Data
Value Unit
Max. temperature, for 15 min at max.
2 bar
90 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temperature, long-term at max.
operating pressure
50 °C
Max. temperature, for 15 min at max.
2 bar
120 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temp.
90 °C
Minimum temperature "Standard"
-10 °C
Data
Value Unit
Max. temp.
90 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temperature, long-term at max.
operating pressure
90 °C
Max. temperature, for 15 min at max.
2 bar
120 °C
Minimum temperature
-10 °C
13.5.2 Air humidity
Data
Value Unit
Maximum air humidity*:
95 % rela‐
tive
humidity
*non-condensing (according to DIN IEC 60068-2-30)
13.6 Housing degree of protection
Data
Value
Protection against contact and humidity*
IP 55
*according to DIN VDE 470 (EN IEC 60529)
TT liquid end
SST - ATEX liquid end
HCT - ATEX liquid end
HCT liquid end
Technical data