1.
Select a suitable motor - it must correspond to the data for
one of the motors from the "Motor data" table - see Chapter
"Technical data".
WARNING!
EX is relevant in areas at risk from explosion!
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
WARNING!
EX is relevant in areas at risk from explosion!
With a claw coupling: The claw on the motor shaft must be
fixed at the correct height, see corresponding figure and
table.
3.
As you have converted an "incomplete machine" into a com‐
plete machine, you must perform a conformity assessment,
risk assessment, issue an EC Declaration of Conformity, fit
your own company nameplate, ... .
4.
With ATEX pumps: additionally perform an ignition hazard
assessment.
5.
Complete the pump documentation / operating instructions.
In areas at risk from explosion only the following combinations of
identity code variants are permitted:
Identity code specification
Values
Elec. power supply / Motor design / Application
4A_ _ 0,
7A_ _ 0,
8A_ _ 0,
9A_ _ 0,
0A_ _ 0
The Declarations of Conformity can be found at the end of the
operating instructions.
If there is an “X” at the end of the ATEX specification of a unit in a
“Declaration of Conformity for ATEX Machines” or a “Declaration of
Incorporation for ATEX Machines”, then special conditions apply
for the safe operation of the equipment in areas at risk from explo‐
sion.
Please refer in this respect to the operating instructions, design
test certificates and other documentation for the bought-in parts!
Install the motor - with designs without
motor
Declarations of Conformity for the
pump
Special conditions X
Safety chapter
23