6
Assembly
–
Refer to the correct dimensional drawings on
our website www.prominent.com for assis‐
tance.
–
Compare the dimensions on the dimensional
drawing with those of the pump.
1.
Select a suitable motor - it must correspond to the data for
one of the motors from the "Motor data" table - see Chapter
"Technical data".
WARNING!
EX is relevant in areas at risk from explosion!
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
WARNING!
EX is relevant in areas at risk from explosion!
With a claw coupling: The claw on the motor shaft must be
fixed at the correct height, see corresponding figure and
table.
3.
As you have converted an "incomplete machine" into a com‐
plete machine, you must perform a conformity assessment,
risk assessment, issue an EC Declaration of Conformity, fit
your own company nameplate, ... .
4.
With ATEX pumps: additionally perform an ignition hazard
assessment.
5.
Complete the pump documentation / operating instructions.
WARNING!
The pump can break through the base or slide off it
– Ensure that the base is horizontal, flat and per‐
manently load-bearing.
Capacity too low
Vibrations can disturb the liquid end valves.
–
Do not allow the base to vibrate.
Install the motor - with designs without
motor
Base
h
P_MOZ_0016_SW
Fig. 7
Assembly
31