9.
Remove the 4 hexagonal head screws and the associated bearing
at both ends of the stator; the rotor is still fitted in the illustration.
B1300
10.
Clean the openings.
1.
Insert the new bearings (3) with their wipers (2) at both ends of the
stator and secure each one with 4 hexagonal head screws (1) -
tightening torque: 6 Nm.
B1301
2.
Clean the rotor, making sure that the rotor is not scratched.
INFORMATION: Never oil or grease the rotor.
3.
Carefully slide the clean and intact rotor into the stator - the end of
the rotor with the groove (*) must then be on the side of the elec‐
trical socket.
B1302
4.
Fit the housing cover with the 4 hexagonal head screws (+
washers), making sure that the side with the ring bolt is facing the
side of the dosing head.
5.
Place the assembly with the motor on the hydraulic block with all the
dowel pins and tighten by means of the side plate with the 4 Allen
screws.
6.
Screw together the rotor and the connector; each component has a
different spanner size (AF24 and AF19).
Assembling the motor