Page 1: ...th controlled solenoid drive optoDrive DLTa or the Operating instructions for the motor driven metering pump Sigma x Control type SxCb EN 982920 BA PM 008 02 18 EN Please carefully read these operatin...
Page 2: ...e PROFIBUS mode 7 3 1 General 7 3 2 Displays 7 3 3 LEDs on the PROFIBUS module 8 3 4 Using the metering monitor 8 4 Assembly and electrical installation 9 5 Operation 11 5 1 General 11 5 2 GSDML File...
Page 3: ...n appears in the operating menu The pump requires a minimum of software version V01 03 06 00 delta DLTa or V01 01 00 00 Sigma Control SxCb and hardware version V01 04 00 00 for the delta for the PROFI...
Page 4: ...PROFIBUS cable to the pump s PROFIBUS socket 2 Press P for 2 seconds on the pump 3 delta only Use the arrow keys to go to Settings and press P 4 Use the arrow keys to go to PROFIBUS and press P 5 Use...
Page 5: ...ia the PROFIBUS to the master PLC Programmable Logic Controller PC etc If the PROFIBUS is set to inactive the settings for the operating mode previously selected are reloaded If the pump is switched t...
Page 6: ...4 Assign a new name via Online diagnostics Fig 2 5 Continue configuring as usual Description of the available objects refer to Operation chapter Setting up installation 6...
Page 7: ...mp is switched to PROFIBUS mode it stops and can only be restarted using the PROFIBUS 3 2 Displays There are other identifiers in the operating display when PRO FIBUS mode is running The current ident...
Page 8: ...o connection to the PROFIBUS Lit green Pump in cyclic mode 3 4 Using the metering monitor The Metering monitor socket must be used to use the metering monitor in PROFIBUS mode The pump then transmits...
Page 9: ...Onvert to the pump s PROFIBUS socket There is no need for terminal resistors Connect the plug in power unit of the DULCOnvert to the mains voltage 1 Unscrew the housing screws and open the cover 2 Scr...
Page 10: ...urfaces of the housing cover and the black seal of the lower part of the housing are free of dirt 2 Replace the housing cover onto the lower part of the housing and fasten in place with the screws 3 C...
Page 11: ...pump can participate in cyclic data transfer Only standard parameterisation is needed for this there are no application specific parameters Please note Data is stored according to the Big Endian prin...
Page 12: ...emory is activated 15 Calibrated Pump is calibrated 16 Relay 1 Relay 1 is physically present 17 Relay 2 Relay 2 is physically present 18 AnalogOut Module is physically present 19 Diaphragm rupture Dia...
Page 13: ...ing frequency in strokes hour 0 12000 The maximum frequency can be significantly lower than in normal mode according to the metering mode set Batch prese lection 10 11 UINT32 Number of strokes in batc...
Page 14: ...m in the dosing head 6 Airlock Air in the dosing head delta only 7 Overpressure Overpressure in the hydraulic system 8 9 10 Low pressure Pressure too low in the hydraulic system delta only 11 Stroke l...
Page 15: ...a transmission in the PROFIBUS 5 4 1 Overview of the data objects The data objects are summarised into modules and their configura tion identifier see following table The configuration identifier allo...
Page 16: ...counter 1 byte Stroke counter 4 bytes Stroke number C0 80 83 14 Delete quan tity counter 1 byte Volume counter Litres per stroke 4 bytes 4 bytes Quantity C0 80 87 Tab 3 Pump data output data Offset Va...
Page 17: ...7 8 high low UINT16 Actual fre quency 0 max freq 9 10 high low UINT16 Maximum fre quency 0 12000 Maximum fre quency 5 11 12 13 14 high low UINT32 Batch prese lection 1 99999 Batching 6 15 16 17 18 hi...
Page 18: ...order If the data of a module is not to be involved in cyclic data transmission then an empty module must be config ured at this point 5 5 Extended diagnostics from the 7th byte The pump uses the mech...
Page 19: ...ss 3rd byte No see Table 2 0x30 OK 0x31 Date outside of limits 0x32 Date protected 0x34 Option not installed 0x35 Service not defined 0x36 Value cannot be changed 0x37 Update completed 0x55 Communicat...
Page 20: ...C Degree of protection IP66 with professional installation PROFIBUS cable length 2 m Plug in power unit length 1 5 m Housing HxWxD 140x110x60 mm without threaded connectors Electrical data Degree of p...
Page 21: ...21...
Page 22: ...22...
Page 23: ...23...