Offset
Value
Type
Name
Area
Module name Modul no.
+15
-
BYTE
Delete stroke
counter
0.1↓
Stroke
number
13
+16
-
BYTE
Delete quan‐
tity counter
0.1↓
Quantity
14
Tab. 4: Pump data (input data)
Offset
Value
Type
Name
Area
Module name Modul no.
+0
+1
+2
+3
high
↓
low
UINT32
Status
see
Status
1
+4
-
BYTE
Mode
see
Operating
mode
3
+5
+6
high
low
UINT16
Frequency
0..max. freq.
Frequency
4
+7
+8
high
low
UINT16
Actual fre‐
quency
0..max. freq.
+9
+10
high
low
UINT16
Maximum fre‐
quency
0..12000↓
Maximum fre‐
quency
5
+11
+12
+13
+14
high
↓
low
UINT32
Batch prese‐
lection
1..99999
Batching
6
+15
+16
+17
+18
high
↓
low
UINT32
Remaining
strokes
1..99999
Remaining
strokes
7
+19
+20
high
low
UINT16
External
factor
0..99999
Transmission
multiplier
8
+21
-
BYTE
Stroke length 0..100↓
Stroke length 9
+22
+23
+24
+25
high
↓
low
FLOAT
Concentra‐
tion (delta
®
only)
0.1ppm..
100%
Concentra‐
tion
11
+26
+27
high
low
UINT16
Error
see
Error /
Warning
12
+28
+29
high
low
UINT16
Warnings
see
Operation
17