Pneumatic
mould
clamping
–
option-
4
X
Warning! Oil drippings and leakages may also develop risks to
the operational safety! The hydraulic system contains high
pressure! Remedy the fault immediately!
Hydraulic oil should be changed twice a year. When changing clean also oil reservoir.
For lubrication of the vibrator bearings use roller bearing grease:
CALYPSOL H 443-HD 88
Multi-purpose greases are
not
appropriate and
should not
be used. In order to avoid any
confusion with unfit greases, use above mentioned grease also for all other greasing points of
the machine.
Alternative greases:
MANUFACTURER
GREASE TYPE
Mobil Oil AG
BP Engergrease LS-EP2
FINA
FINA Marson EPL 3
Dow Corning
Molykote BR2 plus
DIVINOL
Multitherm 2
Deutche BP SG
BP Engergrease LS-EP2
Summary of Contents for UNIVERSAL 1000
Page 19: ...Maintenance manual Universal 1000 P R O M E T A L 19 ...
Page 25: ...Maintenance manual Universal 1000 P R O M E T A L 25 Hydraulic system ...
Page 26: ...Maintenance manual Universal 1000 P R O M E T A L 26 ...
Page 52: ...Maintenance manual Universal 1000 P R O M E T A L 52 Now lower down tamper head and mould ...
Page 53: ...Maintenance manual Universal 1000 P R O M E T A L 53 Pull out cart with mould on itself ...
Page 58: ...Maintenance manual Universal 1000 P R O M E T A L 58 After adjustment is done ...
Page 65: ...Maintenance manual Universal 1000 P R O M E T A L 65 Vibrator table maintenance ...