USER’S MANUAL. PROMAX-10
Premium
Page 32
05/2004
The parameters, which may be changed, and their margins are shown in the
following tables. To change a given parameter turn the rotary selector [9] until the field
is activated (it will appear shadowed) and then press. The value of the parameter will be
activated and may be changed by turning the rotary selector. When the value you want
appears, press the rotary selector [9] to validate it.
DESCRIPTION
PARAMETER
VALUES
Carrier type
MODE FREQ
ANL: Analogue
DIG: Digital
Frequency steps
FREQ STEP
From 0.01 to 10.00 MHz
(Only digital channels)
Digital channel bandwidth
CHANNEL BW
From 0.3 to 9.9 MHz
(Only digital channels)
Frequency where noise is measured
in the C/N measurement.
NOISE FREQ.
± 99.9 MHz (relative mode).
5.00 MHz to 862.00 MHz
absolute mode.
(Only digital channels)
Noise measuring mode.
NOISE MODE
FREQ (Absolute): Noise
level is measured at the
frequency defined by NOISE
FREQ.
BW/2 (Relative): The value
defined by NOISE FREQ. is
added to the tuning frequency.
(Only ANL mode)
CTB measurement mode
CTB SHOWED
IN CH or free channel
(Only ANL mode)
∆
FCS01
∆
FCS01
From ± 0.5 to ± 2.50 MHz
(Only ANL mode)
∆
FCS02
∆
FCS02
From ± 0.5 to ± 2.50 MHz
(Only ANL mode)
∆
FCS03
∆
FCS03
From ± 0.5 to ± 2.50 MHz
(Only ANL mode)
∆
FCS04
∆
FCS04
From ± 0.5 to ± 2.50 MHz
System (according to country)
ANNEX ITU-T
DVB, B, C
QAM Modulation
MODULATION
16, 32, 64, 128, 256
Symbol Rate
SYMBOL RATE
1.000 to 7.000
Attenuation
ATTN.
Auto or from 0 to 60 dB.
(Steps of 10 in 10)
The parameters FREQ. STEP, CHANNEL BW, NOISE FREQ.,
∆
FCSO y
SYMBOL RATE are changed digit by digit, starting at the lowest weight.