CHARGING WITH AC ADAPTOR 

1.

 

Keep all power on/off switches in OFF position while charging. 

2.

 

Completely charge your power station before using it for the first time. 

3.

 

Press test button to check battery voltage 

“VDC”,

 if battery voltage reads <12V, it is necessary to recharge the Power 

Station immediately for smooth running. 

4.

 

Before recharging from an AC outlet, be sure the source is right. (i.e.110 volts or 230 volts) 

5.

 

Use only the chargers provided with unit. 

6.

 

Plug the AC charging cord into any standard wall outlet and the other end into the AC/DC charging input socket. The RED 
LED will illuminate which indicates the unit is charging and it will turn into GREEN LED when it is fully charged. 

First time charge: 

………………………………...

  24 hours 

Recharge and subsequent 

charges……………. Until

 charging LED lights to Green 

 

 

CHARGING WITH DC ADAPTOR 

Due to safety circuits built into the input-charging jack, DC charging through this port will not fully charge the battery. 

1.

 

Keep all power switches in OFF position while charging. 

2.

 

Insert DC adapter plug into charging port of power station and the other end into the cigarette lighter socket of your vehicle. 

The  RED  LED  will  illuminate  which  indicates  the  unit  is  charging  and  it  will  turn  into  GREEN  LED  when  it  is  fully  charged. 

Vehicle should be running for full charging to take place and to avoid draining the battery. 

NOTE: This method allows battery to be topped up during a journey but may not fully charge the unit. Disconnect charging cord 

before turning off engine. NEVER leave vehicle running in an enclosed or poorly ventilated space. 

 

CHARGING WITH SOLAR PANEL 

1.

 

Keep all power switches in OFF position while charging. 

2.

 

Insert the Solar panel connection plug into solar charging port of power station and the other end into the solar panel, 

the RED LED 

will illuminate which indicates the unit is charging. And it will turn to GREEN LED when it is fully charged. 

 

CHARGING TIPS AND WARNINGS 

Keep battery charged, ready for emergencies. Unlike some rechargeable batteries, frequent charging will not harm and in fact, 

will improve the performance of the internal battery. Recharge battery as soon as possible after each use to prolong battery life. 

Frequent heavy discharges between recharging will reduce battery life. Do not leave the Powerstation totally discharged for an 

extended period of time as this can cause battery failure. All lead acid batteries suffer from self-discharge over time, especially 

under extreme temperatures. 

Store in a cool dry place. 

Recharge every 3 months when not in use and more frequently in warmer or colder storage conditions. 

Do not continuously charge the power station for more than 30 hours. Use only the charging adaptors provided with this unit. 

DO NOT OPERATE THE UNIT WHILE CHARGING. 

Summary of Contents for 120

Page 1: ...s 4 To reduce the risk of damage to the cigarette lighter connector and cord do not drag the cord when disconnecting 5 Make sure the cord is safe from being stepped on tripped over or otherwise subjected to damage or stress 6 Do not operate charger with damaged cord or cigarette lighter connector Report it immediately to an authorized Promate service provider or dealer 7 Do not operate the Powerst...

Page 2: ...D ACID battery only Do not connect to a 6 volt or 24 volt battery system Use DC outlet socket to operate 12 volt appliances equipped with a cigarette lighter plug c If battery acid comes in contact with skin rinse immediately with running water then wash thoroughly with soap and water If redness pain or irritation occurs seek immediate medical attention d If battery acid comes in contact with eyes...

Page 3: ...ore first use Failure to do so may permanently damage battery TO READ THE POWER STATION S BATTERY VOLTAGE INVERTER STATUS 1 Press the ON switch button of the power inverter 2 Press test button to read the Power Inverter Battery Voltage status VAC Output AC voltage Hz Output AC frequency Watt Power consumption of the device VDC Battery voltage of power station 3 Recharge the unit when VDC reads 12V...

Page 4: ...ning for full charging to take place and to avoid draining the battery NOTE This method allows battery to be topped up during a journey but may not fully charge the unit Disconnect charging cord before turning off engine NEVER leave vehicle running in an enclosed or poorly ventilated space CHARGING WITH SOLAR PANEL 1 Keep all power switches in OFF position while charging 2 Insert the Solar panel c...

Page 5: ...cal supply store Old batteries should be disposed of properly and safely Please contact your local solid waste authority for recycling information V OPERATING AS A POWER SUPPLY The Promate 120 is capable of supplying power for 220V AC household devices and 12V DC devices up to the rated capacity of the unit The length of time the product will operate depends on the condition of the battery and the...

Page 6: ...this inverter AC receptacle However certain rechargeable devices are manufactured with built in chargers see device owner s manual This category of devices may cause internal damage to inverters and should not be used with this inverter The temperature of the device must be monitored for the first 15 minutes of operation Abnormally elevated temperature of the device is an indication that they shou...

Page 7: ...w 11V This will permanently damage the battery TWO 12V DC PORT The Powers tation is equipped with two outlet socket and can be used to operate most 12 v o l t auto accessories and appliances 11 AMP maximum equipped with a cigarette lighter plug Simply plug in appliance NOTE Socket is live so appliance will be instantaneously powered Length of time appliance will operate depends on the condition of...

Page 8: ...or continued protection against risk of fire replace only with same type and rating of fuse IX TROUBLESHOOTING GUIDE Buzz in Audio Equipment Some inexpensive stereo systems have inadequate internal power supply filtering and may buzz slightly when powered by the power station The best solution to eliminate the buzzing is to use an audio system with a good quality filter Television Interference The...

Page 9: ...ce Overtemperature shutdown Inverter has overheated due to poor ventilation or excessively warm environmentalconditions Turn the AC Outlet On Off switch off and allow Powerstation to cool for 15 minutes or more Clear blocked fan opening or remove objects covering the unit Move to a cooler environment Alarm sounds When inverter used 1 Internal battery is nearly discharged 10 3V 0 3V 2 If you ignore...

Page 10: ...WERTECH ASIA PACIFIC INC Unit 2702 C West Tower PSE Centre Exchange Rd Ortigas Center Pasig City Philippines 1605 FOR SERVICE HOTLINE CALL 02 641 8800 628 1050 WARNING ELECTRIC SHOCK HAZARD Do not remove the housing or disassemble the Powerstation except to replace the internal battery The Powerstation does not contain any internal user serviceable parts and attempting to service the unit yourself...