36
T15
Discrimin.Temp.
Anti-freezing is active from TEV temperatures lower or equal to the temperatures
programmed at this step. In any case, the anti-freezing is always active if TGV <= -
30°C, regardless of TEV value.
During anti-freezing the beater speed is increased to 2 for 30” (fixed).
T21
Set TGV
Value of TGV probe beyond which hot gas heating is disabled.
T24
Max Temp Limit
This is the absolute maximum operating limit for TER and TER2.
When this limit is reached, TTR or TTR2 are deactivated.
T25
Hyst. Max limit
This is the hysteresis for switching on TTR again after reaching the T24 limit.
T29
EVC+EVF Enabling
When TGV reaches the Anti-freezing set (T06), EVGC is activated until temperature
is increased by its hysteresis (T07).
During EVGC activation, EVF and EVF_SUP are deactivated if this step (T29) is set
to No, whereas they remain active if step T29 is set to Yes.
T30
First Defrost Time
In automatic cycles and in manual Cooling, upon reaching the temperature set, the
MC+EVGC hot gas is activated for the time set in this step (in seconds). During this
time, beating remains as previously selected.