27
ALARMS DISPLAYED
The alarm is shown on the second line of the display.
E.g.:
TEV Alarm
The message at the bottom starts blinking, showing that the alarm has been triggered and is
active, whereas it is steady on after the alarm has been reset.
To reset it, press the Decrease button
.
Driver Alarm
Beater Drive Fault
The Drive that activates the beater motor is in alarm: the machine enters
STOP mode and the display reads “Driver Alarm”.
TER Alarm
"TER" temperature probe switched off or short-circuited.
The display will read “Alarm TER" and the machine will enter Stop mode
if “Alarm TER2” is also present.
Check TER temperature probe and replace it if necessary.
Alarm TER2
"TER2" temperature probe switched off or short-circuited.
The display will read “Alarm TER2" and the machine will enter Stop
mode if “Alarm TER” is also present.
Check TER2 temperature probe and replace it if necessary.
Alarm TES
TES Safety thermostat tripping
When the TES Safety Thermostat trips, the machine enters STOP mode
and the display reads “TES Alarm”.
TEV Alarm
"TEV" temperature probe switched off or short-circuited.
The display will read "TEV Alarm" and the machine will enter Stop mode.
Check TEV temperature probe and replace it if necessary.
TGV Alarm
"TGV" temperature probe switched off or short-circuited.
The display will read "TGV Alarm" and the machine will enter Stop mode.
Check TGV temperature probe and replace it if necessary.
Lid Open
Lid Open
When the lid is opened, the machine will not STOP and the display will