Control pendent
Gear shift lever
Spindle lock
Depth stop
Chip protection, with micro switch
Z-axis adjustment wheel
Drive motor
Stable column with
dovetail guides
6-stage reduction gear,
tilted 90 ° right and left
Flexible coolant pipe
Head movement crank
X-axis adjustment wheel
Casted machine stand
with coolant system
Bill of material for the electrical system
Abbreviations Function
Tech. Data
Stk Manufacturer
Comments
QS
Main switch
AC 500V, 16A
1
KANNIE
VDE 0660, IEC 947-3
FU1 / FU 2
Fuse transformer
600V, 2A, 30mm 2
Tend, TFBR-101
30mm
FU 3
Fuse transformer
600V, 3A, 30mm 1
Tend, TFBR-101
30mm
SB 1
Emergency/blanking switch 380V 7.5A
1
A.P.GLEB-221BR EN 6100-3-2
SB 2
Start pushbutton
380V 7.5A
1
A.P. XBG-221AGT EN 6100-3-3
SB 3
Reverse push button switch 380V 7.5A
1
A.P. XGB-221CB
89/336/EEC
SA 3
Pump switch
380V 7.5A
1
A.P. ASS-222
92/31/EEC
SA 2
Dial b / g
380V 7.5A
1
A.P.GCS-2224AB
CSA
SA 1
Speed switch
Itn 16A600V
1
C1R1A
EN 6100-3-2
TP
Terminal boards
AC 600V, 10A
12
A.P. TB-10
UL
M1
Spindle motor
AC 400V
1
3 Ph, Kw 0.75/1.5 IEC 34-1
M2
Pump motor
AC 400V
1
3 Ph, KW 0.1
IEC 34-1
PE
Grounding
SQ1
limit
AC 250V, 6A
1
ENEC
X3M306K2KA
SQ2
Limit
AC 250V, 6A
1
ENEC
X3M306K2KA
KM1/ KM2
Spindle motor contactor
600V, 4Kw, 24V
1
Riken, 12T01E1
IEC 408, VDE 0660
KM3
Pump motor contactor
600V, 4Kw, 24V
1
Riken, 12T01E1
IEC 408, VDE 0660
FR
Overload protection
2.9 - 4.3A
1
Riken, BTH-18T
VDE0660, EN60947-5-1
TC
Transformer
AC 400/24V 72VA 1
SUENN LIANG
IE76-8, EN60947-5-1
KA
Relay
Coil AC24V/AC240V 5A
1
OMRON, MY-2J
VDE 9903UG
PL
Indicator light
AC 24V 15W
1
A.P. PLN-2230W
89/336EEC
Power cable
1.25mm2
control cable
0.3mm2
Main Controls