1. GENERAL INFORMATION
Attention
: All users must read these operating
instructions carefully prior to the initial operation. These
instructions are intended to acquaint the user with the
hoist controller and enable him/her to use it to the full
extent of its intended capabilities.
The operating instructions contain important information
on how to handle the hoist controller in a safe, correct and
economic way. Acting in accordance with these
instructions helps to avoid dangers, reduce repair costs
and downtime and to increase the reliability and lifetime of
the hoist controller.
Anyone involved in doing any of the following work with
the hoist controller must read the operating instructions
and act accordingly:
• Operation, including preparation, trouble shooting and
cleaning
• Maintenance, inspection, repair
• Transport
Apart from the operating instructions and the accident
prevention act valid for the respective country and area
where the hoist controller is used, also the commonly
accepted regulations for safe and professional work must
be adhered to.
The user is responsible for the proper and professional
instruction of the operating personnel.
Suitable for entertainment use
The
PRO
LYFT AETOS hoist controllers are specially
designed for use in the Entertainment industry. They must
only control electric chain hoists that are suitable for use
in the Entertainment industry.
Combining the hoist controller with different type of
electric chain hoists might lead to unwanted, unexpected
or dangerous situations.
The
PRO
LYFT AETOS hoist controllers are not designed
to control hoists suspending or lifting loads above people.
Read the manual of the electric chain hoists before
starting to operate them with the hoist controller.
Regulations
The accident prevention act and/or safety regulations of
the respective country for using manual and electric chain
hoists must be strictly adhered:
• Europe:
• Machine Directive 2006/42/EG
• Safety of Machinery NEN 12100:2010
• Germany: BGV D6, BGV D8
Additional regulations are in effect for lifting or suspending
loads over people.
Germany: SQ P2
The Netherlands: NPR8020-10
United Kingd
om: BS7950-1
Maintenance/Repair
In order to ensure correct operation, not only the
operating instructions, but also the conditions for
inspection and maintenance must be complied with. If
defects are found or abnormal noise is to be heard stop
using the hoist controller immediately.
Attention:
Before starting to work on electrical
components the power-supply is to be cut off.
2. INCORRECT OPERATION
•
Do not
exceed the rated power capacity per controlled
channel.
•
Do not
lift stuck or jammed loads.
•
Do not
shortly and frequently actuate the up/down
switch.
• Do not
control hoists if the movement of the load is not
visible from the operating position.
• Do not
control hoists if you are skilled for lifting loads
• Do not
use cables with damaged strain reliefs and/or
isolation.
• Do not
use any input- or output cables that are not
suitable for the supplied voltage and / or current.
• Do not
use the Thuja data connection (link in, link out)
with other network devices unless these devices are
specified to be suitable for use in the Thuja data
network.
• Do not
connect the controller to a mains connection that
is not properly fused.
• Do not
use the controller without proper grounding.
• Do not
connect more then one hoist on a single
channel.
3. ELECTRIC CONNECTIONS
All electric connections must be used with respect for the
specified voltages and maximum power consumption.
Power input:
The power input connector is a 5pin CEEform connector
suitable for 3 phase 32Amp / 400Volt. 3 Phases, neutral
and ground.
Depending on the type of controller it can be plugged in to
either a 3 phase 400V or a 3 phase 230V mains
connections.
Make sure the mains connection is fused at maximum
32Amps per phase. It is advised to use circuit breakers
with a C or D characteristic.
Make sure the mains connection is properly grounded.
Improper grousing might lead to dangerous with the
risk
of electric shock.
Maximum power consumption per hoist.
Each hoist channel is capable of switching an electric
chain hoist with maximum power consumption of 1,5kW.
Power output to the hoists
For each 4 hoist channels there is a Harting 16 output
connector.
Make sure the cables (and each individual wire of the
cable) connected to the output connector are suitable for
minimum 10Amps at 400V per wire.
To avoid voltage drops longer cables should have bigger
wire diameters.
page
!
4
AETOS
Range
AETOS
Range
26
12. SPARE PARTS: Aetos 1000 Low Voltage
Part nr.
Catalogue code
PAE-1000LV
Description
1
PAE-S-671152
GEAR ASSY AETOS 1000
2
PAE-S-671157
MOTOR SPACER AETOS 1000
3
PAE-S-BC1000-
01C+PAE-S-
BC1000-05
BRAKECOVER AETOS 1000 CO
BRAKECOVER GASKET AETOS 1000
4
PAE-S-MC1000-
01C+PAE-S-
MC1000-05
MOTORCOVER AETOS 1000 CO
MOTORCOVER GASKET AETOS 1000
5
PAE-S-671139
MOTOR ASSY 400-230V, 3PH, 50-60HZ
AETOS 1000
6
PAE-S-671174
BOARD ASSY. F. LV CONTROL AETOS 500
+1000
7
PAE-S-610032
TRANSFORMER PRI.400-230V SEC.24V
9
PAE-S-671171
CHAIN WHEEL COVER ASSY AETOS 1000
10
PAE-S-671159
CHAIN WHEEL COVER SEALING AETOS 1000
11
PAE-S-671161
GASKET MOTOR SPACER AETOS 1000
12
PAE-S-670757
CHAIN GUIDE HALF AETOS 1000
13
PAE-S-670190
LOAD WHEEL 7,1X20,5 CHAIN
14
PAE-S-671106
CHAIN STRIPPER AETOS 1000
15
PAE-S-670356
LIMIT SWITCH WIRE SEAL AETOS 500-1000
16
PAE-S-670152
SPACER BUSH 30X25X5 AETOS 1000
17
PAE-S-9120055
DISC SPRING 50x25,4x1,25 AETOS 1000
18
PAE-S-670148
CLUTCH HUB ASSY AETOS 1000
19
PAE-S-9151139
BAL BEARING 6002 DIN625 T1
20
PAE-S-671215
ASSEMBLED CONTROL LINE AETOS 500
+1000
21
PAE-S-671216
ASSEMBLED POWER LINE AETOS 500-1000
22
PAE-S-671150
DISENTANGLE PLATE AETOS 1000
23
PAE-S-671183
DISENTANGLE PLATE INSERT AETOS 1000
24
PAE-S-670395
ANCHOR COVER PLATE AETOS 1000
25
PAE-S-671158
LIMIT SWITCH ADAPTER AETOS 1000
26
PAE-S-671042
MICRO SWITCH ASSY AETOS 1000
Part nr.
Catalogue code
PAE-1000LV
Description
27
PAE-S-671194
BLIND PLUG SQUARE BLACK AETOS 500-
1000
28
PAE-S-671198
BRAKE BFK457-08 AETOS 1000
29
PAE-S-671164
SUSPENSION HOOK ASSY AETOS 1000
30
PAE-S-671044
FASTENING STRAP
31
PAE-S-9131069
KEY 5X5X20 DIN6885-A
32
PAE-S-671145
CABLE GLAND WITH ANTIKINK FITTING
33
PAE-S-780537
SEALING DISC FOR M20
34
PAE-S-9184106
LOCK NUT GMP-GL-M20X1,5
35
PLT-10-010
TAG LRP125 RFIP,25MM FOR HOIST
36
PLS-033050011
PLASTIC RING 5Xd 5,3X25X2,5
38
PAE-S-9104131
BOLT M3x8 INBUS 8.8 ISO10642
39
PAE-S-9102313
BOLT M6x30 INBUS 8.8 DIN 6912
40
PAE-S-9102281
BOLT M6x16 INBUS 8.8 DIN6912
41
PAE-S-9102054
BOLT M8x25 INBUS 8.8 DIN7984
42
PAE-S-9102306
BOLT M8x35 INBUS 8.8 DIN6912
43
PAE-S-9102301
BOLT M8x50 INBUS 8.8 DIN6912
44
PAE-S-9101718
BOLT M8x30 INBUS 8.8 DIN7984 PRECOTE
80
45
PAE-S-9108066
BOLT M6x16 INBUS 10.9 ISK ISO7380 LENS
HEAD
46
PAE-S-9101719
BOLT M3x6 INBUS 8.8 DIN 7984
47
PAE-S-670185
LOAD PIN AETOS 1000
48
PAE-S-9123027
RETAINING RING DIN6799-15-FST
49
PAE-S-9129033
RETAINING RING DIN471-14x1
50
PAE-S-9129043
RETAINING RING DIN471-34x1,5
51
PAE-S-9129023