Proluxe Apex Pro X1 Operation Manual Download Page 8

 

LED   segment   check  
(8888)   then   to  
version   #   and   then  
loops   back   to   to   the  
above   reboot.  

Digital   display   shows  
PROB.   No   heat   on  
upper   platen.  
 

Sensor   lost   it's   continuity   as   shown  
on   a   muti-meter.  

Disconnect   prob   that   is   open   (no  
continuity   as   shown   on   a   multi-  
meter.   Must   replace   sensor  
(RTD).   Do   not   cut   and   splice   new  
sensor.   Install   new   2000   ohm  
RTD   sensor   to   under   side   of   heat  
platen   and   reconnect   to   the  
controller.  
 

A1.10  

When   depressing   the  
tactile   button  
on   digital   controller,  
nothing   happens.  
 

The   tactile   buttons   under   the   overlay  
may   be   not   close   enough   to   activate.  
Same   goes   if   the   buttons   are   already  
pressed   by   overlay   without  
depressing   button.  
 

Carefully    tighten   the   nuts   on   the  
back   of   the   controller   until   button  
activate.   Same   goes   in   reverse   if  
buttons   are   held   down   by   the  
overlay.  

----  

Press   does   not   close  
when   pressing   the  
two,   green,   start  
buttons  

1.   Did   not   simultaneously   press   the  
start   buttons   exactly   at   the   same  
time.  
 
2.   The   lower   platen   switch   mounted  
on   the   base   is   not   in   contact   to  
complete   circuit.  
 
 

Try   pressing   both   buttons   exactly  
at   the   same   time.   This   is   a   safety  
feature.  
 
2.   Make   sure   the   roller   plunger  
comes   into   contact   (clicking  
noise).   This   is   also   a   safety   feature  
that   both   platens   are   aligned.  

 
82  

Digital   display   shows  
relay   and   particular  
zone   is   overheating.   

1.    The   relay   on   the   switched   side   is  
not   opening   to   regulate   temperature.  

1.    Replace   the   relay.  

92  

Beeper   not  
functioning  

1.     Beeper   on   digital   control   board  
failed.  

1.     Replace   digital   controller  
board.  

76  

If   setpoint   is   reached  
but   slightly   off   in  
temperature.  

Offset   may   need   to   be   calibrated   and  
adjusted.  

Call   (800)   624-6717   ext.   129   for  
instructions.  

 

Heater   platen  
overheating  

If   the   relay   (depending   on   the   year   of  
the   model)   on   the   coil   side   are  
receiving   12vdc   indicates   the  
controller   is   functioning   properly.   On  
the   switching   side   of   the   relay,   is  
there   120   vac   going   to   the   heater   in  
question.   If   there   is   no   voltage   on  
the   to   the   switching   side   of   the   relay  
to   the   heaters,   the   relay   is   not  

Replace   relay   If   the   controller's  
heat-on   LED   is   not   lit   indicating  
the   controller   is   working  
properly.  
 

55  

Summary of Contents for Apex Pro X1

Page 1: ...Operations Manual Apex Pro X1 Hydraulic Automatic Dough Press Model DP1350 WWW PROLUXE COM Version 122820...

Page 2: ...itself Limited Machine Warranty Proluxe warrants this dough press machine when operated under normal conditions to be free from manufacturing defects in material and workmanship for a period of one ye...

Page 3: ...arth Terminal Borne de terre de protection Caution Warning chaud avertissement S A F E T Y S U M M A R Y Warning To reduce the risk of electrical shock do not remove or open cover No user serviceable...

Page 4: ...ectrique remplacer avec le m me type et calibre du fusible Mis fusible suppl mentaire nominale max 3A 120 Vac Caution Hot Avoid touching hot surfaces while operating the machine Attention chaud vitez...

Page 5: ...ss MODE button until the time is displayed Press and hold SET button while pressing the UP and DOWN arrow buttons to desired timer setting 4 Resetting the Counter Press MODE button until the counter i...

Page 6: ...or harsh abrasives it will you will cause costly damage 1 Before cleaning make sure the unit is turned off 2 Spray lower platen with approved food release oil spray 3 Wipe excess oil across upper and...

Page 7: ...power cord into wall receptacle and power button 2 Reset circuit breaker that the grill is plugged into Depress power button to turn on 3 Replace Transformer after you check secondary side of transfo...

Page 8: ...platen switch mounted on the base is not in contact to complete circuit Try pressing both buttons exactly at the same time This is a safety feature 2 Make sure the roller plunger comes into contact c...

Page 9: ...as not to damaging closing platens After alignment is complete re install locking set screw as not to move the alignment set screw 17 Dough is not a consistent thickness Adjust upper platen for level...

Page 10: ...3X 35 36 126 39 40 2X 41 42 50 44 45 59 47 48 49 50 51 52 3X 53 4X 54 4X 55 4X 56 57 57 58 58 58 46 60 61 2X 62 63 4X 63 4X 64 4X 64 4X 65 66 2X 67 68 69 70 72 73 76 4X 77 4X 78 81 86 83 85 86 86 88 8...

Page 11: ...130 129 22 2X 107 107 3 109 82 125 93 4X 6 16 4X 17 4X 4 18 106 4X 125 125 21 38 117 16 79 80 84 16 84 108 74 115 4X 5 119 116 120 121 122 124 114 114 119 118 118 128 4X 132 EXPDP1350 RH 051820 CUSTO...

Page 12: ...WSAE38 WSAE38 WSAE38 WSAE38 1 25 WASHER LOCK 3 8 WL38 WL38 WL38 WL38 WL38 WL38 WL38 WL38 WL38 WL38 2 26 NUT HEX 3 8 16 NH3816 NH3816 NH3816 NH3816 NH3816 NH3816 NH3816 NH3816 NH3816 NH3816 2 28 SCREW...

Page 13: ...111 110969111 110969111 110969111 110969111 110969111 110969111 4 77 WASHER STEEL 311150019 311150019 311150019 311150019 311150019 311150019 311150019 311150019 311150019 311150019 4 78 SWITCH PROXIM...

Page 14: ...F 2 110559029 110559029 110559029 110559029 110559029 110559029 110559029 110559029 110559029 110559029 1 122 NUT CONDUIT 1 2 NC12 NC12 NC12 NC12 NC12 NC12 NC12 NC12 NC12 NC12 1 123 SCREW SET 1 4 20 X...

Page 15: ......

Page 16: ......

Page 17: ...s the unit is still under the 1 year manufacturer warranty R E T U R N E D M E R C H A N D I S E P O L I C Y Should it become necessary to return any of the company s products the following instructio...

Page 18: ...be made by purchaser at time goods are received If goods are damaged the PURCHASER shall request that the agent of the transportation company make a written notation on the proper shipping documents i...

Reviews: