![Proluxe Apex Pro X1 Operation Manual Download Page 7](http://html1.mh-extra.com/html/proluxe/apex-pro-x1/apex-pro-x1_operation-manual_1615622007.webp)
Refilling hydraulic oil:
Recommended ISO/AW46 Hydraulic oil
Capacity of Reservoir is 650 ml
Remove threaded breather, fill 200 ml at a
time and add as desired. Replace threaded
breather.
Troubleshoot Guide - Model #: DP1350
Problem
Cause
Action
Ref #
Power button on
digital controller face
is depressed but
doesn’t turn on.
1. Power cord is not plugged in.
2. Circuit breaker is tripped off in the
site's breaker box.
3. Transformer has taken an
electrical surge and is damaged.
4. Check voltage on the secondary
side of the transformer. If you read
12VDC then you are receiving
voltage to the controller.
5. Possible blown fuse.
1. Plug the power cord into wall
receptacle and power button.
2. Reset circuit breaker that the
grill is plugged into. Depress
power button to turn on.
3. Replace Transformer after you
check secondary side of
transformer. If working properly,
you should receive 12vdc.
4. Replace controller. Controller
should be on once the power
button is depressed.
5. Replace fuse.
60
-----
66
76
39
Digital controller's
LED's are scrambled
or randomly erratic.
If when turning on,
the display will first
go to segment check
1. Possibly a component on the
Digital controller is damaged.
2. Control needs to reset.
Replace digital controller.
While unit is on unplug unit, wait
for 1 min. Then plug machine on
again and depress power button.
-----
76
Digital controller on
startup goes through
The relay driver on the digital control
may be blown.
Replace digital controller.
76