• POWER CABLE WIRING

1. Extend the 

RED 

wire to the  + VBAT. 

2.  Properly connect the 

BLACK 

wire to the ground. 

3. Connect the Functional Wires to your controller or switching 

unit depending on the functions needed for application. 
Applying  +VBAT to any functional Wire will activate its 
function. 

-

PS

IT: 

10106 

dd 

WARNING!  Do not remove/change the 
factory configured fuse attached at the 
terminal of the RED wire without notice. 

• WARNING  LIGHTS

1. 

Apply the  + VBAT to #1, #2 

or 

#3 wire to activate 

Mode 1,  Mode 2, or Mode 3 

2.Apply the  + VBAT to #8 wire to activate Front Corners 

3.Apply the  +VBAT to #9 wire to activate Rear Corners 

• FLASH PATTERNS

1. Connect the  + VBAT to #1, #2 

or 

#3 wire to activate 

Mode 

1, 

Mode2, or Mode 3 

2.  To advance the flash pattern by applying 

#4 

wire to a 

+ VBAT momentary switch or top the 

#4 

wire to  + VBAT 

for  1 second. 

3. Flash pattern will be reset when 

#4 

wire is connected to 

+ VBAT for more than 5 seconds. 

• ALLEY LIGHTS

1. Applying  + VBAT to the #11 wire will activate the Left Alley. 

2. Applying  + VBAT  to the #12 wire will activate the Right Alley. 

3. Alley  Lights override warning modes. 

NOTE: 

To configure the patterns of CRUISE ALL 

MODE,  T RAFFIC ARROW and TAKE DOWN, make 

sure only one desired function wire is connected to 
the  + VBAT,  and then top the #4 wire(flash pattern 
wire) to  + VBAT for  1 second. 

• TRAFFIC ARROW

l. Apply  +VBAT  to the #18 wire will activate the Left Arrow. 

2. Apply  +VBAT to the #19 wire will activate the Right Arrow. 

3. Apply  +VBAT  to the #20 wire will activate  the Outside­

in Arrow. 

4. Centre out mode is activated by connecting both #18 & #19 

wires to  +VBAT. 

5. With the desired traffic arrow wire connecting to  + VBAT, 

advance the pattern for each mode by tapping the 

#4 

wire to 

+VBATfor  1 second. 

NOTE: 

Arrow function overrides all warning modes 

an all rear-facing modules (not including corners). 

• DIMMODE

Activate Dirn  Mode by applying 

#5 

wire to  +VBAT  to operate 

lighting at reduced intensity of 50% brightness. Traffic Arrow, 

Takedown,  alley  lights and flood lights are not affected. 

• FLOODMODE

Apply desired Flood Mode wire to  +VBAT for activation of each 
of 5 modes. Flood modes override flashing. 

1. Activate Flood Front by applying #13 wire to  +VBAT. 

2. Activate Flood Front&Corners by applying #14 wire to  + VBAT. 

3. Activate Flood Rear by applying #15 wire to  +VBAT. 

4. Activate Flood Rear&Corners by applying #16 wire to  + VBAT. 

5. Activate Flood All by applying #17 wire to  + VBAT. 

• CRUIS E MODE

1. Activate the Cruise Corner mode by applying #6 wire to  + VBAT. 

2. Activate the Cruise All mode by applying #7 wire to  +VBAT. 

3. With 

#7wire 

connecting to  +VBAT,  apply#4to  +VBATfor 

1 second to advance the pattern of the Cruise All mode. 

• TAKEDOWN

1. Apply  +VBAT to the #10 wire to activate the factory configured 

takedown function. 

2.  To advance the takedown pattern by tapping the 

#4 

wire to 

+VBATfor l  second. 

• S TOP /TAIL/TURN

lf lig htbar is built with stop/tail/turn modules as specified at time of 
order,  separate control wires are included to control stop,  tail,  left 
turn and right turn. ST T  overrides flashing 

1. Activate Stop Light by applying #21 wire to  + VBAT. 

2. Activate Tail Light by applying #22 wire to  + VBAT. 

3. Activate Left Turn by applying #23 wire to  +VBAT. 

4. Activate Right  Turn by applying #24 wire to  +VBAT. 

• SMART PARK

Activate Smart Park by applying #25 wire to  +VBAT to operate 
lighting at reduced intensity of 50% brightness with 60  fpm 
single flash. 

NOTE: 

Smart Park can only be activated when 

Werning Model  or Werning Mode2 is on. 

P6 

-

www.prolux-shop.com

www.prolux-shop.com

Summary of Contents for Skyline AIR S

Page 1: ...SKYLINE AIR S X6 Vl 0 1NSTALLATION MAINTENANCE SERVICE MANUAL ProLux Systemtechnik GmbH Co KG Am Schinderwasen 7 D 89134 Blaustein Tel 49 0 7304 9695 100 ...

Page 2: ...at a high rate of speed or walk on or around traffic Iones 7 The equipment is intended for use by authorized personnel only The user is responsible for understanding and obeying all laws regarding emergency warning devices Therefore the user should check all applicable city state and federal laws and regulations The manufacturer assumes no liability for any lass resulting from the use of this warn...

Page 3: ...Traffic Arrow Takedown alley lights and flood lights not affected Corner Modules 50 brightness All Modules 50 brightness flash once every 3 seconds Activotes front facing flashing modules corners Activotes reor facing floshing modules corners Override flashing Activates left alley lights Steady burn overides flashing Activates right alley lights Steady burn overides flashing Activates the flood mo...

Page 4: ...ght Arrow 3 Apply VBAT to the 20 wire will activate the Outside in Arrow 4 Centre out mode is activated by connecting both 18 19 wires to VBAT 5 With the desired traffic arrow wire connecting to VBAT advance the pattern for each mode by tapping the 4 wire to VBATfor 1 second NOTE Arrow function overrides all warning modes an all rear facing modules not including corners DI MMODE Activate Dirn Mode...

Page 5: ...arefully remove the lightbar and mounting kits and place them on a flat surface examine the unit and components before installation Slide the hex bolt through the hook bracket hole See figure l Using the socket wrench to loosely secure the hook bracket to the foot bracket with the hex bolt Repeat on the other side of the lightbar so both sides have the hook brackets loosely secured Piece the light...

Page 6: ...www prolux shop com www prolux shop com ...

Page 7: ...6 574 8282 2560 E mail sales 911signal com Your Innovative and Reliable Partner www 911signal com Scan QR Code and Get a Free One Year Extension of Warranty ProLux Systemtechnik GmbH Co KG Am Schinderwasen 7 D 89134 Blaustein Tel 49 0 7304 9695 60 INSTALLATION MANUEL DE MAINTENANCE ET SERVICE ProLux Systemtechnik GmbH Co KG Am Schinderwasen 7 D 89134 Blaustein Tel 49 0 7304 9695 60 ...

Page 8: ...élevée ou de respecter la signalisation au sol L équipement est destiné à être utilisé uniquement par du personnel autorisé L utilisateur est responsable de la compréhension et du respect de toutes les lois concernant les dispositifs d avertissement d urgence Par consé quent l utilisateur doit vérifier toutes les lois et réglementations municipales provinciales et fédérales applicables Le fabrican...

Page 9: ...ants flèche défilement droite Remplace les modes flashants flèche défilement extérieur vers intérieur Remplace les feux STOP Remplace les feux de position Remplace le clignotant gauche Remplace le clignotant droit Mode feux de détresse avec intensité jusqu à 50 simple flash fréquence 60 flashs par minute Connecter le fil marron au feu de pénétration droit pour synchronisation Connecter le fil marr...

Page 10: ... ORG 1 et ORG 2 à VBAT 5 Avec le fil de flèche de trafic souhaité connecté à VBAT faites avan cer le modèle pour chaque mode en appuyant sur le fil BLU 4 sur VBAT pendant 1 seconde 1 Active le mode faible intensité en connactant BLU 5 au VBATpour réduire l intensité à 50 de sa valeur maximale N affecte pas les flèches défilantes les feux de zone latéraux et les modules faisceaux large 1 Appliquez ...

Page 11: ...rte du véhicule se ferme sans aucune interférence En utilisant les deux trous pilotes à l extrémité du support de crochet comme gabarit percez 2 trous dans le toit à l aide d un foret de taille appropriée et fixez le support au véhicule avec des vis taraudeuses de chaque côté Voir la figure 2 MONTAGE PERMANENT Retirez soigneusement la rampe lumineuse et les kits de montage et placez les sur une su...

Page 12: ...s centraux Dissipateur de chaleur Silent bloc Cabochon gauche Reflecteurs centraux Cylindre de fixation rondelle plate PCB Cabochon du milieu Patte de fixation rondelle ressort Reflecteur d angle Cabochon droit Vis Écrous Joint d étanchéité Support de modules droits Crochets de fixation www prolux shop com www prolux shop com ...

Reviews: