Installation: Diffusion Director
9. Make sure that the “S” shaped injector tube is turned upwards near the
center of the duct, as shown in Fig. 24.
10. If more than one 5’ duct section is used, the elbow and reducer are placed on top of the final exten-
sion. After the first segment, each segment requires only one additional mounting bracket, situated
12” down from the top.
11. Connect black injector hose (P/N 10606) from the top of the enclosure to the end of the “S” shaped
injector conduit. Ensure that the “S” shaped injector conduit is situated as shown. (Fig. 25)
Fig. 24 Fig. 25
12. Hold the control box (P/N 10437) against the wall, so that the top is flush with the top of the appliance
and that there is about 12 inches between them. Use a level to ensure the box is leveled. Mark the
holes. (Fig. 26)
Fig. 26 Fig. 27 Fig. 28
13. Install nylon anchor screws (P/N 10600) at marked holes. Then, mount the control box to the wall using
screws (P/N 6614) and washers (P/N 10605). Connect the fan power cord to the connector in the con-
trol box. For mounting in concrete, drill 5/16” holes. Secure using anchors (P/N 10439), screws (P/N
10440), and washers (P/N 10605). (Fig. 27)