E.  Programming the Air/Q 1100-Avian  

Programming is simple from instructions on the machine itself.  Basically, you can program start and stop 
times and the intensity level. 

1.  Scent intensity can be adjusted from 1 to 50.   Turn the power on and use the +- keys to change inten-

sity.  For spaces smaller than 150,000 cubic feet consult the Settings Table below.  It is only a guide and 
subject entirely to conditions in the space. 

Settings Table

Output Level Range Settings Space to be treated  

(in Cubic Feet)

Space to be treated  
(in Cubic Meters)

1 thru 5

1,800-8,000

50-230

6 thru 10

8,000-17,000

230-480

11 thru 15

17,000-28,000

480-790

16 thru 20

28,000-40,000

790-1,130

21 thru 25

40,000-53,000

1,130-1,500

26 thru 30

53,000-69,000

1,500-1,900

31 thru 35

69,000-86,000

1,900-2,400

36 thru 40

86,000-104,000

2,400-3,000

41thru 45

104,000-126,000

3,000-3,600

46 thru 50

126,000-150,000

3,600-4,200

2.   Start times can be set by turning the dial to start and then using the +- keys to set the start time.   The 

Stop time is set the same way.  

Hint: There are many variables involved in finding the right settings 
for Avian Plus.  The installer should experiment to determine the 
lowest setting level that is effective in controlling birds.  Start low 
and move it up as needed until the birds scram.  

F.  The Last Step

1.  Set the dial to either 24/7 (recommended) or Program if you have programmed a start/stop time (see 

Commissioning the Air/Q Avian on page 6 for details). 

2.  Make sure the power is on. The blue light will show through the button. 

3.  Close and lock the door, storing the key in a known place.

8

Bird Control General Considerations

Summary of Contents for Air/Q 1100-Avian

Page 1: ......

Page 2: ...t B Installation Objective C How Many Machines D Positioning Considerations E Programming VII Installation Fragrance Director Attachment 9 VII Installation Direct Indoor Fan 10 A Installation Kit B Pr...

Page 3: ...ist droplet insuring uniform distribution of scent without leaving residues on exposed sur faces The Air Q 1100 Avian is computer controlled and programmable to automatically maintain a constant scent...

Page 4: ...ply The UL and CE compliant power supply converts power to 12V DC to power the appliance 6 Unplug before cleaning For online safety instructions visit www prolitec com manuals manuals htm B Avian Plus...

Page 5: ......

Page 6: ......

Page 7: ...hol C Air Filter every 6 months or as needed Replace air filter part number 10417 if dirty If any dust has gathered inside the unit remove it with a damp paper towel D Battery Replacement approx every...

Page 8: ...he dial to 24 7 24 7 Mode is recommended because it is assumed that the openings which allow the entry of birds remain even when the structure is not operational If this is not the case you can progra...

Page 9: ...resh air you may need more machines D Positioning of the appliances for wall mounting must consider the following 1 Direction of air currents in the space It is important to not fight the natural air...

Page 10: ...00 1 130 1 500 26 thru 30 53 000 69 000 1 500 1 900 31 thru 35 69 000 86 000 1 900 2 400 36 thru 40 86 000 104 000 2 400 3 000 41thru 45 104 000 126 000 3 000 3 600 46 thru 50 126 000 150 000 3 600 4...

Page 11: ...en you probably want an Extend able Director with sufficient extensions to come within 5 to 10 of the ceiling For example if the ceiling height is 50 and the rafters range from 40 to 50 off the floor...

Page 12: ...vian appliance not pictured with 2 Four 4 dry wall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall and concrete 5 F...

Page 13: ......

Page 14: ......

Page 15: ...se output port located on the top left of the appliance but no more than 4 1 2 feet above it Fig 3 2 Use the Diffusion Fan assembly as a template to mark the location of the mounting holes Fig 4 3 For...

Page 16: ...Fig 11 If needed use a flat head screw driver to push in the side wall of the cable raceway Fig 12 Fig 13 Fig 14 7 Insert cable connector into jack located on the right side of the appliance Fig 12 8...

Page 17: ......

Page 18: ......

Page 19: ...nstallation 1 The appliance is wall mounted Place the appliance onto the desired location on the wall and ensure that it is level 2 Fasten the appliance to the wall using necessary screws 3 Connect th...

Page 20: ......

Page 21: ...tween the nuts and the bracket 4 Mount the duct body P N 10424 onto the top of the fan Use a level to make sure the body is situated vertically Slip another mounting bracket around the body about 12 u...

Page 22: ...end of the S shaped injector conduit Ensure that the S shaped injector conduit is situated as shown Fig 25 Fig 24 Fig 25 12 Hold the control box P N 10437 against the wall so that the top is flush wi...

Page 23: ...let and the control box and the outlet For instructions on installing the raceway see pages 12 13 16 Plug in both the appliance and the control box Turn on appliance Press the to set the intensity lev...

Page 24: ...Q 1100 Avian appliance not pictured with 2 Four 4 dry wall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall and conc...

Page 25: ......

Page 26: ......

Page 27: ...y upward through to the waterproof collar Fig 1 on p 11 6 Lube the inside of the grommet if needed to allow the Injector hose to easily slide through Leave ap proximately 2 inches of hose length insid...

Page 28: ...ee 10 sheet metal screws 5 Turn the appliance on and verify that a plume is produced 6 Before attaching the Injector hose to the injector verify that the plume can flow easily through the in jector Th...

Page 29: ...g the space The O Rings on the stem that fits into the head may be worn out and causing an air leak Increase the output rate by one or two settings and evaluate detection in 30 minutes Repeat as neede...

Page 30: ...nty tool and rolling on the new ones You detect the fragrance when entering the room but after a while you no longer notice it This is called olfactory adaptation and is normal Leave the area for 5 to...

Page 31: ...er Input Input 100 240 VAC at 0 6 A Frequency 50 60 Hz Protection Switching power supply Internal Power 12 VDC at 1 5 A Back up battery Lithium 3V CR2032 Performance Up to 150 000 cu feet 4 200 cu met...

Page 32: ...2 cm Duct Diameter x Height 4 inch x 5 foot section 10 2 cm x 152 4 cm Diffusion Director 4 inch x 16 inch 10 2 cm x 40 6 cm Weight with mounting hardware 3 5 pounds 1 6 kg Weight each additional 5ft...

Reviews: