Configure the 6201-WA-DFNT 150 Module
6201-WA-DFNT
♦
ProLinx Wireless
High Speed Wireless EtherNet/IP Gateway
ProSoft Technology, Inc.
Page 17 of 45
August 12, 2008
The corresponding Consume command on the DFNT Client 151 looks like this:
This command states:
Receive 600 words of data with each exchange ID = 1002 from IP:
172.16.10.150 and place them in 600 registers beginning at database register
1200. Receive data within 400 ms using UNICAST.
The second Consume command is set up the same way. It must correspond to
the second Produce command in order to accept the data coming from it.
The first Produce commands on the
DFNT Client 151
correspond with the first
Consume commands on the DFNT Client 150. The corresponding command
looks like this:
This command states:
Send 600 words of data beginning at data register 0 to 172.16.10.150 (the DFNT
Client 150) using an exchange ID of 1000. Send data every 100 ms using
UNICAST.
Note: The sample configuration file also shows an additional Produce and Consume command.
These commands are designed to pass a time value from the DFNT Client 150 to the DFNT Client
151 module and then loop back from the DFNT Client 151 to the DFNT Client 150. These
commands are included for testing and radio communication verification purposes only and are not
necessarily required for your application.
How it's Done
1
Double-click on the
icon.
2
Click the Add button. ProSoft Configuration Builder adds a default row.