- 2 - INSTALLATION
2.1 MOUNTING
KRYPTON may be set up on a solid and even surface. The unit can also be mounted upside down to a
cross arm. For fixing, stable mounting clips are required. The mounting place must be of sufficient stability
and be able to support a weight of 10 times of the unit’s weight.
The unit must be installed so that nobody will be able to look directly into the laser beam. Already a
short radiation on the retina may cause permanent damage. Unintentional reflections must be prevented.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the fixture’s being used.
•
Install the projector at a suitable location by means of the mounting bracket (1).
•
Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
•
Adjust the projector and use the knob (2) to slightly release or tighten the locking mechanism of the
bracket if is necessary.