PROLIGHTS - ArcPod
48Q
09
Fig. 05 - Example configuration (Output at 230 V)
MALE POWER
IP67 CONNECTOR
FEMALE POWER
IP67 CONNECTOR
N
L
E
L
N
E
MAINS 230V
Unit 1
Unit 2
Unit 3
Unit 4
POWER
IN
POWER
IN
POWER
IN
POWER
IN
POWER
OUT
POWER
OUT
POWER
OUT
POWER
OUT
NOTE: when not using the Power output connectors, you must seal the cable ends with the sup-
plied caps.
Fig. 04
5 - CONNECTION TO THE MAINS SUPPLY
WARNING: For protection from electric shock, the fixture must be earthed!
The product is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 Volts.
If you need to install a power plug on the power cable to allow connection to power outlets, install a
grounding-type (earthed) plug, following the plug manufacturer’s instructions. If you have any doubts
about proper installation, consult a qualified electrician.
The max power consumption is 521W.
You can link up tp 2 units at 120 V; 4 at 230 V. Never exceed this number. Power linking cords can be
purchased separately.
When connecting the unit to a local power, it may be necessary to use the Schuko to IP67 adapters
supplied with this product.
Core (EU)
Core (US)
Connection
Plug terminal marking
Brown
Black
Live
L
Blue
White
Neutral
N
green
Green
Earth
E