background image

PROLIGHTS - ArcPod 

48Q

22

Problems

Possible causes

Checks and remedies

Product doesn’t power ON •  No power to the product. •  Check that power is switched ON and cables are 

plugged in.

•  Fuse blown or internal 

fault.

•  Check if the Fuse is intact and eventually replace it if 

necessary.

• 

Contact  the  MUSIC  &  LIGHTS  Service  or  authorized 

service partner. Do not remove parts and/or covers, or 

carry out any repairs or service that are not described 

in this Safety and User Manual unless you have both 

authorization from MUSIC & LIGHTS and the service 

documentation.

Product reset correctly but 

does not

respond correctly to the 

contoller.

• 

Bad signal connection.

•  Inspect connections and cables. Fix eventual bad 

connections. Repair or replace damaged cables.

•  Signal connection not 

terminated.

• 

Insert DMX termination plug in signal output socket of 

the last product on the signal line.

•  Incorrect addressing of 

the product.

•  Check the product address and control settings.

•  One of the product is 

defective and is corrupt

-

ing the signal transmis

-

sion on the signal line.

• 

Unplug  the  XLR  in  and  out  connectors  and  connect 

them directly together to bypass one product at a 

time until normal operation is regained. Once found 

the  error,  have  that  fixture  serviced  by  a  qualified 

technician.

Timeout error after fixture 

reset.

•  One or more hardware 

components requires 

mechanical adjustments.

•  Check product stored error messages for more 

information. Contact MUSIC & LIGHTS Service or an 

authorized service partner.

Mechanical effect loses 

position

• 

Mechanical 

hardware 

require cleaning, adjust

-

ment or lubrification.

•  Check product stored error messages for more 

information. Contact MUSIC & LIGHTS Service or an 

authorized service partner.

Light output turn OFF 

Intermittently

•  Fixture is too hot.

•  Check product stored error messages.

•  Allow product to cool.

• 

Clean the product and airflow filters.

•  Reduce ambient temperature.

•  Hardware failure (tem

-

perature sensor, fans, 

Light source...).

•  Check product stored error messages for more 

information. Contact.

• 

MUSIC  &  LIGHTS  Service  or  an  authorized  service 

partner.

General low light intensity

•  Dirty lens assembly.

• 

Dirty or damaged filters.

• 

Clean the fixture regularly.

•  Install lens assembly properly.

Contact an authorized service center in case of technical problems or not reported in the table can not 

be resolved by the procedure given in the table.

TROUBLESHOOTING

Summary of Contents for ArcPod 48Q

Page 1: ...USER MANUAL REV 02 07 21 English version ArcPod 48Q 48x10W RGBW FC outdoor IP66 LED wash light for exterior installations ...

Page 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights it or can be inquired to the official PROLIGHTS distributors of your territory https www prolights it sales_network html Scanning the below QR Code you will access the download area of the product pag...

Page 3: ... DMX LINE 10 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 10 CONNECTION DAISY CHAIN OF THE DMX LINE 10 DMX ADDRESSING 11 7 RDM FUNCTIONS 11 8 OPERATION VIA DATAMASTER 12 RDM SETTING 12 STAND ALONE FUNCTION 13 9 DMX CHARTS 14 10 ACCESSORIES INSTALLATION 18 LENS CODE S27QLENS10 15 25 45 18 LIGHT DIFFUSION FILTER CODE A48QFILTER 19 BARN DOOR CODE S48QBD OPTIONAL 20 11 MAINTENANCE 21 MAINTENANCE AND CLE...

Page 4: ... are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are damaged defective deformed or showing signs of overheating Do not reapply power until repairs have been completed Refer any service operation not described in this manual to PROLIGHTS Service team or ...

Page 5: ...rranty T 80 C c Temperature of the external surface The surface of the fixture can reach up to 80 C 176 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture Us...

Page 6: ...oducts to which this manual refers comply with 2014 35 EU Safety of electrical equipment supplied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS ...

Page 7: ...4 7 cm A48QFILTER6010 60 X10 asymmetric light diffusion filter for ARCPOD48Q and ARCPOD96Q 15x44 7 cm A48QFILTER6030 60 X30 asymmetric light diffusion filter for ARCPOD48Q and ARCPOD96Q 15x44 7 cm S27QLENS10 10 lens for SOLAR27Q ARCPOD27Q SOLAR48Q ARCPOD48Q ARCPOD15Q and ARCPOD96Q S27QLENS15 15 lens for SOLAR27Q ARCPOD27Q SOLAR48Q ARCPOD48Q ARCPOD15Q and ARCPOD96Q S27QLENS25 25 lens for SOLAR27Q A...

Page 8: ...PROLIGHTS ArcPod 48Q 06 2 TECHNICAL DRAWING 584 mm 23 0 in 304 mm 12 0 in 93 mm 3 7 in 190 mm 7 5 in 250 mm 9 8 in Fig 01 Weight 14 kg 30 86 lbs ...

Page 9: ...re that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping the fixture to a truss or other structure at any angle use clamps of half cou pler type Do not use any type of clamp that does not completely encircle the structure when fastened 584 mm 23 0 i...

Page 10: ... 1 POWER IN for connection to a mains 100 240V 50 60Hz The max power consumption is 120W 2 DMX IN 3 pole 1 GND 2 sign 3 sign 3 DMX OUT 3 pole 1 GND 2 sign 3 sign 4 POWER OUT power output for connection of multiple units in series Fig 03 1 2 3 4 ...

Page 11: ... automatically adjusts to any 50 60Hz AC power source from 100 240 Volts If you need to install a power plug on the power cable to allow connection to power outlets install a grounding type earthed plug following the plug manufacturer s instructions If you have any doubts about proper installation consult a qualified electrician The max power consumption is 521W You can link up tp 2 units at 120 V...

Page 12: ...t to your DMX network it is necessary to use the adapters XLR 5 pin IP67 signal connector supplied with this product CONNECTION DAISY CHAIN OF THE DMX LINE Connect the DMX data output from the DMX source to the product DMX input male connector Run the data link from the product DMX output female connector connector to the DMX input of the next fixture Terminate the data link by connecting a 120 Oh...

Page 13: ...DM protocol allows data packets to be inserted into a DMX512 data stream without affecting existing non RDM equipment It allows a console or dedicated RDM controller to send commands to and receive messages from specific fixtures The PIDs in the following tables are supported in the product Parameter PID GET SET DEVICE_INFO 0x0060 x DEVICE_MODEL_DESCRIPTION 0x0080 x MANUFACTURER_LABEL 0x0081 x DEV...

Page 14: ...l distance to less than 60 m 197 ft Otherwise you might need to use an RDM optically isolated signal amplifier RDM SETTING To set the RDM functions with the DATAMASTER follow these steps Turn on the DATAMASTER Select the RDM function Wait the discovering of all units Select the desired unit and press ENTER button Change the value of the desired function The following chart describes the RDM menu t...

Page 15: ...nual Color or Effect function Select Head 1 Select the desired color or effect with speed The projector where is setted the STAND ALONE values is a MASTER projector If there isn t the DMX controller or the DMX missing this projector will send his STAND ALONE value on the DMX line On others units that will be connected to the same DMX line must NOT be setted the STAND ALONE they will be SLAVE and t...

Page 16: ...el 5 Ch 7 Ch 10 Ch 1 RED DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 DIMMER SPEED MODE WHITE WHITE 6 STROBE STROBE 7 DIMMER SPEED MODE COLOR MACRO 8 EFFECTS 9 EFFECTS SPEED 10 DIMMER SPEED MODE 9 DMX CHARTS ...

Page 17: ... 5600k 6000k 6500k 7000k 8000k 9000k 10000k 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 000 8 EFFECTS No Function Effect 1 Effect 2 Effect 3 Effect4 Effect5 Effects1 4 Effect 6 Effect 7 Effect 8 Effect 9 Effects6 8 000 010 011 037 038 064 065 091 092 118 119 145 146 172 173 1...

Page 18: ...STROBE 4 6 GREEN 2 RED 1 7 BLUE 2 GREEN 1 8 WHITE 2 BLUE 1 9 RED 3 WHITE 1 10 GREEN 3 RED 2 11 BLUE 3 GREEN 2 12 WHITE 3 BLUE 2 13 RED 4 WHITE 2 14 GREEN 4 RED 3 15 BLUE 4 GREEN 3 16 WHITE 4 BLUE 3 17 DIMMER SPEED MODE WHITE 3 18 RED 4 19 GREEN 4 20 BLUE 4 21 WHITE 4 22 DIMMER SPEED MODE ROW SECTIONS ROW 1 ROW 2 ROW 3 ROW 4 ...

Page 19: ...000 4 9 WHITE 1 0 100 000 255 000 5 10 RED 2 0 100 000 255 000 6 11 GREEN 2 0 100 000 255 000 7 12 BLUE 2 0 100 000 255 000 8 13 WHITE 2 0 100 000 255 000 9 14 RED 3 0 100 000 255 000 10 15 GREEN 3 0 100 000 255 000 11 16 BLUE 3 0 100 000 255 000 12 17 WHITE 3 0 100 000 255 000 13 18 RED 4 0 100 000 255 000 14 19 GREEN 4 0 100 000 255 000 15 20 BLUE 4 0 100 000 255 000 16 21 WHITE 4 0 100 000 255 ...

Page 20: ... the screws Then remove the front glass 2 rubber seal 3 lens holder 4 and the lens 5 2 Replace the lenses by inserting the two pins on the back of the lens DETAIL with the holes pro vided on the PCB LED 5 NOTE to reassemble the lenses reverse the procedure NOTE it is recommended to tighten the front cover screws carefully so as to guarantee the correct IP degree Fig 09 ...

Page 21: ... front cover 1 by loosing the screws Then remove the front glass 2 and the rubber seal 3 Place the light diffusion filter 4 on the lenses 5 NOTE to remove the light diffusion filter reverse the procedure NOTE it is recommended to tighten the front cover screws carefully so as to guarantee the correct IP degree Fig 10 ...

Page 22: ...1 2 Insert the two marked pin on down edge of the barn door into the holes provided on the unit 1 and positioning the spring pin on the hardware into the hole provided on the top 2 3 4 Hook the safety cable 3 and adjust the angle of the four leafs 4 Fig 11 ...

Page 23: ...d according to various factors such as the amount of the use and the condition of the installation environment It is recommended that the product is subject to annual service by a qualified technician for special maintenance involving at least the following procedures General cleaning of internal parts All other service operations on the product must be carried out by MUSIC LIGHTS its approved ser...

Page 24: ...rs and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact MUSIC LIGHTS Service or an authorized service partner Mech...

Page 25: ...Note ...

Page 26: ...Note ...

Page 27: ......

Page 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190 ...

Reviews: