8 - OPERATION VIA DATAMASTER
The unit uses a DATAMASTER for configuration purposes. The diagram below sows how to connect the
DATAMASTER to this product. This connection will control multiple products at the same time.
To set different Stand Alone mode on different product, you must connect the DATAMASTER to each
product, individually.
However, by using the DATAMASTER, you may address each product in the daisy chain to a different
DMX address by using the RDM function without the need connect to each individual product.
Important: The DATAMASTER must be used to configure this product.
MUSIC & LIGHTS suggests that you connect no more than 11 units in this mode and keep the total
distance to less than 60 m (197 ft). Otherwise, you might need to use an RDM optically isolated signal
amplifier.
RDM SETTING
To set the RDM functions with the DATAMASTER follow these steps:
•
Turn on the DATAMASTER;
•
Select the "RDM" function;
• Wait the discovering of all units;
• Select the desired unit and press ENTER button;
• Change the value of the desired function.
The following chart describes the RDM menu tree of the product, the terms shown in
BOLD
indicates
the default settings.
MENU
1
START ADDRESS
0
01
-512
2
PERSONALITY
5 Ch
7 Ch
10 Ch
17 Ch
722 Ch
3
DIMMER MODE
Off
Dimmer1
Dimmer2
Dimmer3
4
PWM
MODULATION
600Hz
1200Hz
2000Hz
4000Hz
6000Hz
25kHz
Select PWM fre
-
quency.
6
SPECIFIC PIDS
8200
White Balance-Red
125 ÷
255
8201
White Balance-Green
125 ÷
255
8202
White Balance- Blue
125 ÷
255
8203
White Balance- White
125 ÷
255
8206
Clean Device Hours
0-1
0: No
1: Yes
8217
Full On mode
0-1
0: HB Mode
1: Studio Mode