4.1 Cleaning the unit and maintenance

•  Make sure the area below the installation place is free from unwanted persons during set-up.
•  Switch off the unit, unplug the main cable and wait until the unit has cooled down.
•  All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded.
•  Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any deformation.
•  When the lens is visibly damaged due to cracks or deep scratches, it must be replaced.
•  The main cables must be in impeccable condition and should be replaced immediately even when a 

small problem is detected.

•  In order to protect the device from overheating the cooling fans (if any), and ventilation openings should 

be cleaned monthly.

•  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
•  It is recommended to clean the plastic panel of the unit at regular intervals, from impurities caused by 

dust, smoke, or other particles to ensure that the light is radiated at maximum brightness. For cleaning, 
disconnect the main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then 
carefully wipe the plastic pane dry. For cleaning other housing parts use only a soft, clean cloth. Never 
use a liquid, it might penetrate the unit and cause damage to it.

Warning: we strongly recommend internal cleaning to be carried out by qualified personnel!

- 4 -  MAINTENANCE

Summary of Contents for ARCLED2033

Page 1: ...Version 3 0 11DMXchannels I GB Manuale Utente User Manual ARCLED2033 Led colour changer ...

Page 2: ...REV 010 10 09 11CH ...

Page 3: ...tica per interni ed esterni INDICE Sicurezza Avvertenze generali Attenzione e precauzioni per l installazione Informazioni generali 1 Descrizione e specifiche tecniche 1 1 Elementi di comando e collegamenti 1 2 Descrizione 1 3 Specifiche tecniche 2 Installazione 2 1 Montaggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazioni base 3 3 Funzionamento in modalità automatica 3 4 Collegamento...

Page 4: ...he la temperatura delle parti non possa provocare ustioni attendere almeno 30 minuti dallo spegnimento È assolutamente necessario proteggere l unità per mezzo di una fune di sicurezza Nell eseguire qualsiasi intervento attenersi scrupolosamente a tutte le normative in materia di sicurezza vigenti nel paese di utilizzo Evitare di ostruire l ingresso e l uscita dell aria L unità deve essere posizion...

Page 5: ...zioni 4 POWER IN cavo per il collegamento alla rete 230 V 50Hz 5 Ingresso dei segnali DMX XLR a 3 poli 6 Uscita dei segnali DMX XLR a 3 poli per il collegamento con l ingresso DMX di un ulteriore unità effetti 7 Manopola di regolazione staffe fig 1 Fig 1 1 2 3 A B 5 6 4 7 1 1 Elementi di comando e collegamenti 1 DESCRIZIONE E SPECIFICHE TECNICHE ...

Page 6: ...tinua tivo anche in condizioni termiche critiche Sospensione e fissaggio posizionamento per mezzo della doppia staffa regolabile in dotazione Alimentazione 230V 50Hz cavo di alimentazione senza terminale Assorbimento energetico e tempe ratura di lavoro contenuta Indice di protezione IP65 Corpo alluminio pressofuso e acciaio compatto e leggero trasformatori per lampada non richiesti Dimensioni WxHx...

Page 7: ...er mezzo della base di montaggio fig 2 Per orientare l uni tà allentare le viti di bloccaggio 7 impostare l inclinazione desiderata e stringere nuovamente le viti L area di collocazione deve avere una stabilità sufficiente e supportare almeno 10 volte il peso dell unità 2 INSTALLAZIONE ...

Page 8: ...ne C Premere il tasto ADDRESS per impostare i valori 0 9 nella posizione indicata dal punto led lampeggiante Per entrare nella modalità 2 premere il tasto FUNCTION Premere il tasto ADDRESS per impostare i valori 00 63 relativi all indirizzo ID Per entrare nella modalità 3 premere il tasto FUNCTION quando si è nella modalità 2 Premere il tasto ADDRESS per impostare i valori 01 13 relativi alla scel...

Page 9: ...lor changing Dimmer and color mixing Adjustable parameters Speed 1 4 10 2 sec Speed 1 4 10 2 sec Speed 1 4 10 2 sec Speed 1 4 10 2 sec Speed 1 4 120 5 sec DMX value 1 8 9 16 17 24 25 32 33 40 41 48 49 56 57 64 65 72 73 80 81 88 89 96 97 104 105 112 113 120 121 128 129 136 137 144 145 152 153 160 Program no 6 13 Strobe Program 6 Program 7 Program 8 Program 9 Program 10 Functions Red Green Blue Red ...

Page 10: ...ciò comportereb be malfunzionamenti delle unità e dei controller Per passaggi lunghi può essere necessario l inserimento di un amplificatore DMX In tal caso è sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poichè non è in grado di trasmettere in modo affidabile i dati di controllo DMX Collegare l uscita DMX del controller con l ingresso DMX della prima unità Collegare quindi ...

Page 11: ...l nostro esempio l indirizzo 28 Mediante i tasti FUNCTION e AD DRESS è possibile impostare il valore dell indirizzo Non appena si ricevono i segnali dall unità di comando DMX il display indica l indirizzo di start e l unità cambiacolori può quindi essere comandata dall unità di comando DMX Inoltre per lo stesso indirizzo ID è possibile associare 64 Sub ID In questo modo le unità possono rispondere...

Page 12: ...I cavi di alimentazione devono essere in condizione impeccabile e dovrebbero essere sostituiti immedia tamente nel momento in cui anche un piccolo problema viene rilevato Al fine di proteggere l unità da surriscaldamento le ventole di raffreddamento e nel caso le aperture di ventilazione devono essere pulite mensilmente L interno del dispositivo deve essere pulito ogni anno utilizzando un aspirapo...

Page 13: ...door applications INDEX Safety General instructions Warnings and installation precautions General information 1 Description and technical specifications 1 1 Operating elements and connections 1 2 Description 1 3 Technical specifications 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Set up 3 3 Operation without DMX controller 3 4 Linking 3 5 Connection of the DMX line 3 6 C...

Page 14: ...s and installation precautions Never look directly at the light beam Before starting any maintenance work or cleaning of the unit cut off power from the main supply Make certain that the fixture is off and the temperature of the components cannot cause burns wait at least 30 min utes after switching off Always additionally secure the projector with the safety rope When carrying out any work always...

Page 15: ...r different functions depending on the mode of operation 3 Button B address to change settings 4 POWER IN cable for connecting to the network 230 V 50Hz 5 DMX signal input XLR 3 pin 6 Output signals DMX XLR 3 pin for connection to the DMX input of an additional unit effects 7 Adjusting knob bracket Fig 1 Fig 1 1 2 3 A B 5 6 4 7 ...

Page 16: ... source 33 x 1W high efficiency LEDs 10 red 12 green 11 blue No infrared emission no ultraviolet emission Optical units powerful light output by means of special lenses Projection angle 45 25 available on request LEDs estimated life 100000 hours Illumination Intensity 2500 Lx at 1m Control DMX 512 protocol through 3 poles XLR connection 11 channels Master slave mode built in synchronized shows Dim...

Page 17: ...2033 can be fixed as shown below on pic 2 using the base support To adjust its inclination it s necessary to tighten down the knobs 7 Be sure that the mounting place is enough stable and strong before fixing it 2 INSTALLATION Fig 2 7 A B ...

Page 18: ...t 00 for SLAVE mode or 01 for MASTER mode Please note for an easy access setting by holding for 5 seconds the FUNCTION button is possible to return to MODE1 from MODE1 or MODE2 return to MODE3 from MODE3 MODE4 or MODE5 3 1 Operation Connect the supplied main cable to a socket 230 V 50 Hz Then the unit is ready for operation and can be operated via a DMX controller or independently displays its sho...

Page 19: ...1 4 10 2 sec Speed 1 4 10 2 sec Speed 1 4 120 5 sec DMX value 1 8 9 16 17 24 25 32 33 40 41 48 49 56 57 64 65 72 73 80 81 88 89 96 97 104 105 112 113 120 121 128 129 136 137 144 145 152 153 160 Program no 6 13 Strobe Program 6 Program 7 Program 8 Program 9 Program 10 Functions Red Green Blue Red Green Green Blue Adjustable parameters Strobe 1 4 no strobe 0 3 sec 1 sec 5 sec Strobe 1 4 no strobe 0 ...

Page 20: ...nected to the system s earth as this would cause faulty fixture and controller operation Over long runs can be necessary to insert a DMX level matching am plifier For those connections the use of balanced microphone cable is not recommended because it cannot transmit control DMX data reliably Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX inp...

Page 21: ... the next possible start address for the following DMX controlled unit the address 28 could be used for this example By using FUNCTION and ADDRESS buttons it is possible to set up the start address Once the unit receives a signal for the control unit the display will show the current start address value Moreover for same start address further 64 Sub ID address are available If the DMX value of the...

Page 22: ...all problem is detected In order to protect the device from overheating the cooling fans if any and ventilation openings should be cleaned monthly The interior of the device should be cleaned annually using a vacuum cleaner or air jet It is recommended to clean the plastic panel of the unit at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is rad...

Page 23: ...chi conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the unit in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Abstract General Guarantee Conditions Please remem...

Page 24: ...date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purchased by Acquistato da SURNAME COGNOME Dealer s stamp and signature Timbro e firma del Rivenditore NAME NOME ADDRESS VIA N CITY CITTA Purchasing date Data acquisto PROV ZIP CODE C A P ...