Montageanleitung /
Installation manual
MBN GmbH
Balthasar-Schaller-Str. 3
86316 Friedberg
Germany
www.proled.com
2. Configuration Diagram:
3. Set initial DMX-Address
Accept DMX512 signal only when the DIP switch FUN=OFF, as figure 1
DIP
1
2
3
4
5
6
7
8
9
VALUE
001
002
004
008
016
032
064
128
256
REMARK
DMX512 initial address is the total amount of the Dip switch 1-
9, down dip switch to “ON” position,
User can get its place value, Up dip switch to “OFF” position, Its place value is 0.
Example: Set initial address to 37
Set the 1st , 3rd, 6th, bit of the DIP switch downward to
“1”the rest to “0” (like figure 2), the
summation from 1 to 9 is 1+4+ 32, so the DMX512 initial address code is 37.