background image

 

 

5

 

The symbols on the micro inverter are list below and illustrated in detail. 

Symbol 

Usage

 

 

Treatment   

To comply with European Directive 2002/96/EC on waste 
Electrical and Electronic Equipment and its implementation as 
national law, electrical equipment that has reached the end of 
its life must be collected separately and returned to an 
approved recycling facility. Any device no longer required must 
be returned to an author zed dealer or approved collection and 
recycling facility. 

 

Caution   

Do not come within 8 inches (20cm) of the  micro inverter for 
any length of time while  it is in operation.   

 

Danger of high voltages  

Danger to life due to high voltage in the micro inverter.   

 

Beware of hot surface  

The inverter can become hot during operation. Avoid contact 
with metal surfaces during operation. 

 

CE mark  

The inverter complies with the requirements of the Low Voltage 
Directive for the European Union. 

 

Read manual first  

Please read the installation manual first before installation, 
operation and maintenance. 

Summary of Contents for Prosol-M600

Page 1: ...V1 1 1 User Manual MICRO INVERTER Prosol M600 PROJOY ELECTRIC SRL...

Page 2: ...BLY INSTRUCTION 10 Step 1 Install Micro inverter 10 Step 2 Connect AC Cable of Micro inverter 10 Step 3 Protecting Unused Ends 10 Step 4 Connecting AC TRUNK Cables to Junction Box 11 Step 5 Drawing Sy...

Page 3: ...everal inverters this system is built for the incorporation of a Micro inverter for each photovoltaic module Each Micro inverter works independently of the others to guarantee maximum power of each ph...

Page 4: ...ion that can result in deadly electric shock hazards other serious physical injury or fire hazards Indicates directions which must be fully understood and followed in entirety in order to avoid potent...

Page 5: ...returned to an author zed dealer or approved collection and recycling facility Caution Do not come within 8 inches 20cm of the micro inverter for any length of time while it is in operation Danger of...

Page 6: ...nnected in the input of the inverter Do not connect batteries or other sources of power supply The inverter can be used only if all the technical characteristics are observed and applied Do not instal...

Page 7: ...the inverter contact the supplier or authorized distributor for are pair return determination and instructions regarding the process 3 2 CHECK INSTALLATION ENVIRONMENT Installation of the equipment is...

Page 8: ...all only on structures specifically conceived for photovoltaic modules supplied by installation technicians Install Micro inverter underneath the photovoltaic modules so that they work in the shade If...

Page 9: ...STALLING DIAGRAM System Schematic Diagram Fig 2 230Vac single phase Assembly Diagram Fig 3 Assembly Illustration DC AC Red Live Black Neutral Green Ground PV Module Micro inverter AC Cable Junction Bo...

Page 10: ...cable section The Micro inverter must be under the module out of long term exposure to direct sunlight or rain Step 2 Connect AC Cable of Micro inverter Connect the AC cable of the Micro inverters The...

Page 11: ...box caps adapters etc must be made with securely sealed Projoy components Projoy AC cables from the Micro inverters have three conductors with different colors to identify the function of each conduct...

Page 12: ...priate position on the diagram found in the Appendix of this manual Fig 7 System Map Step 6 Install Photovoltaic Modules Install the photovoltaic modules and connect the DC cables of the modules to th...

Page 13: ...modules so that the Micro inverters can operate in the shade Direct sunlight may cause damage to the Micro inverters Each module must be connected to the Micro inverters with a DC cable having a lengt...

Page 14: ...igned to allow internal repairs The AC output wiring harness AC drop cable on the Micro inverter cannot be replaced If the cord is damaged the equipment should be scrapped Maintenance operations must...

Page 15: ...its per 20A Branch 7 Maximum output overcurrent protection A 20 Maximum output fault current ac and duration Efficiency Peak inverter efficiency 96 3 CEC weighted efficiency 95 5 Nominal MPPT efficien...

Page 16: ...com APAC Branch ProJoy Electric Co Ltd XinTang Industrial Zone PingJiang District Suzhou China Tel 86 512 6878 6489 Fax 86 512 6878 6489 Website www projoy electric com Email Sales projoy electric com...

Reviews: