6.1 TECHNICAL DATA 

Model

 

Prosol-M600

 

Input data(DC) 

 

Recommended input power (W) 

200~310/200~310 

MPPT voltage range (V) 

27~48 

Operating voltage range (V) 

16~60 

Maximum input voltage (V) 

60 

Maximum input current (A) 

10/10 

Inverter back feed current (A) 

Output Data (AC) 

 

Rated output power (W) 

500 

Rated output current (A) 

2.17 

Nominal output voltage/range (V) 

230/200-270 

1

 

Nominal frequency/range (Hz) 

50/45.5-54.5

1

 

Power factor 

>0.99 

Output current harmonic distortion 

<3% 

Maximum Units per 20A Branch  

Maximum output overcurrent protection (A) 

20 

Maximum output fault current (ac) and duration 

 

Efficiency 

 

Peak inverter efficiency 

96.3% 

CEC weighted efficiency 

95.5% 

Nominal MPPT efficiency 

99.5% 

Night time power consumption (mW) 

<50 

Mechanical Data 

 

Dimensions (W×H×D mm) 

252×250×28 

Weight 

2.8kg 

Type of Enclosure 

IP67 

Cooling 

Natural Convection 

Environmental Data

 

 

Operating Ambient Temperature Range

 

-40°C to 65°C 

Operating Internal Temperature Range 

-40°C to 85°C 

Relative Humidity 

0-100 % condensing 

Maximum Operating Altitude without Derating 

2000m 

ADD Pollution Rating 

Overvoltage Category    

OVC II for PV input circuit, OVC III for mains 
circuit 

Protective class 

 

 

Summary of Contents for Prosol-M600

Page 1: ...V1 1 1 User Manual MICRO INVERTER Prosol M600 PROJOY ELECTRIC SRL...

Page 2: ...BLY INSTRUCTION 10 Step 1 Install Micro inverter 10 Step 2 Connect AC Cable of Micro inverter 10 Step 3 Protecting Unused Ends 10 Step 4 Connecting AC TRUNK Cables to Junction Box 11 Step 5 Drawing Sy...

Page 3: ...everal inverters this system is built for the incorporation of a Micro inverter for each photovoltaic module Each Micro inverter works independently of the others to guarantee maximum power of each ph...

Page 4: ...ion that can result in deadly electric shock hazards other serious physical injury or fire hazards Indicates directions which must be fully understood and followed in entirety in order to avoid potent...

Page 5: ...returned to an author zed dealer or approved collection and recycling facility Caution Do not come within 8 inches 20cm of the micro inverter for any length of time while it is in operation Danger of...

Page 6: ...nnected in the input of the inverter Do not connect batteries or other sources of power supply The inverter can be used only if all the technical characteristics are observed and applied Do not instal...

Page 7: ...the inverter contact the supplier or authorized distributor for are pair return determination and instructions regarding the process 3 2 CHECK INSTALLATION ENVIRONMENT Installation of the equipment is...

Page 8: ...all only on structures specifically conceived for photovoltaic modules supplied by installation technicians Install Micro inverter underneath the photovoltaic modules so that they work in the shade If...

Page 9: ...STALLING DIAGRAM System Schematic Diagram Fig 2 230Vac single phase Assembly Diagram Fig 3 Assembly Illustration DC AC Red Live Black Neutral Green Ground PV Module Micro inverter AC Cable Junction Bo...

Page 10: ...cable section The Micro inverter must be under the module out of long term exposure to direct sunlight or rain Step 2 Connect AC Cable of Micro inverter Connect the AC cable of the Micro inverters The...

Page 11: ...box caps adapters etc must be made with securely sealed Projoy components Projoy AC cables from the Micro inverters have three conductors with different colors to identify the function of each conduct...

Page 12: ...priate position on the diagram found in the Appendix of this manual Fig 7 System Map Step 6 Install Photovoltaic Modules Install the photovoltaic modules and connect the DC cables of the modules to th...

Page 13: ...modules so that the Micro inverters can operate in the shade Direct sunlight may cause damage to the Micro inverters Each module must be connected to the Micro inverters with a DC cable having a lengt...

Page 14: ...igned to allow internal repairs The AC output wiring harness AC drop cable on the Micro inverter cannot be replaced If the cord is damaged the equipment should be scrapped Maintenance operations must...

Page 15: ...its per 20A Branch 7 Maximum output overcurrent protection A 20 Maximum output fault current ac and duration Efficiency Peak inverter efficiency 96 3 CEC weighted efficiency 95 5 Nominal MPPT efficien...

Page 16: ...com APAC Branch ProJoy Electric Co Ltd XinTang Industrial Zone PingJiang District Suzhou China Tel 86 512 6878 6489 Fax 86 512 6878 6489 Website www projoy electric com Email Sales projoy electric com...

Reviews: