North America

Eaton

9PX3000RT

120

120

2.7

L5-30P

5-20R, L5-30R

Liebert

GXT4-3000RT120

120

120

2.7

L5-30P

5-20R, L5-30R

Worldwide

Manufacturer

Model

Voltage

In

Voltage

Out

kW

Input

Connector

Output Connector(s)

APC

SRT3000XLW-IEC

208/230

230

2.7

C20

IEC C13, IEC C19

Eaton

9PX3000GRT

208/230

230

3.0

C20

IEC C13, IEC C19

 

Any UPS unit will impose additional facilities considerations including battery storage,  oor space, interconnect and electrical receptacle
requirements.   For example, the above North-America UPS models require an L5-30 receptacle.

 

If additional or substitute cordsets are required, the cordset shall be rated greater than or equal to the input current rating of the product at the
voltage applied.  For example, a C13 to C14 cordset will be required if the UPS provides C13 receptacles (typical in markets outside North America).

 

Recognizing that customer needs and facilities differ greatly, 3D Systems encourages customers to contact one of the above UPS manufacturers for
a power protection solution tailored to the customer and site needs.

 

ProJet® XL Finisher (Optional) Power Requirements

The ProJet® XL Finisher must be hardwired and installed by a Certi ed Electrician. For more information about the ProJet® XL Finisher click 

here

.

 

Client Workstation Requirements

Before a print can be printed on the printer, the print data  le must be saved or exported to the industry-standard .stl  le format, and submitted over
the network. 3D SPRINT client software is located on 3DS Central can be installed on each intended users’ workstation to allow them to select,
preview, and submit jobs; as well as manage the print queue. For more information on sending a  le to the 3D printer system see the ProJet® MJP
2500 User’s Guide available on:

 

http://infocenter.3dsystems.com/projetmjp2500/user-guide

 (Acrylate)

 

http://infocenter.3dsystems.com/projetmjp2500w/user-guide

 (Wax)

Prior to installing the software, ensure that the initially selected workstation meets the following minimum speci cations. Although the ProJet®
2500 client software will run on less powerful computers, meeting the minimum recommended con guration will ensure acceptable performance. It
is recommended that this workstation be further enhanced with the recommended requirements for maximum performance, particularly with more
powerful processors and added memory.

System Requirements

OS

Minimum

- Windows 7 (64-bit)

-Windows 8 (64-bit)

-Windows 10 (64-bit)

Recommended

 

 

 

CPU

- Intel or AMD processor with
a minimum of 2.0GHz

- Multiple core processor

- Hyper threading and clock speeds above 3GHz
can be bene cial but should be paired with a good
balance of cores.

Summary of Contents for MJP 2500

Page 1: ...back to http infocenter 3dsystems com projetmjp2500 facility requirements guide for the most up to date facility requirements guide About This Manual This document includes the overall facility requir...

Page 2: ...Descriptions of hardware software part material networking components and documentation that comprise the ProJet MJP 2500 Professional Printing System An overview of the site requirements in typical e...

Page 3: ...l before touching Access panels are for service only and should be opened only by certi ed service personnel or trained maintenance personnel THIS GLOBAL HARMONIZED SYSTEM LABEL FOR LOW LEVEL TOXICITY...

Page 4: ...ontaining the following accessories and materials Two Build Platforms one on the printer and one in an accessory box Region speci c country kit consisting of one power cable Two full cartridges of Vis...

Page 5: ...oved ____ Network connection s ____ Power outlet s a dedicated circuit to power the 3D printer system ____ Storage cabinetry for extra 3D printer system material containers and other consumables ____...

Page 6: ...use of a dedicated circuit that will allow for 100 127 VAC 50 60 Hz 15A single phase or 200 240 VAC 50 Hz 10A single phase Single C14 receptacle All ProJet MJP 2500 series printers relies on a connect...

Page 7: ...about the ProJet XL Finisher click here Client Workstation Requirements Before a print can be printed on the printer the print data le must be saved or exported to the industry standard stl le format...

Page 8: ...assigned IP address A DHCP server automatically programs an IP address otherwise a network administrator can manually assign a permanent IP address for each printer that is to be connected to the net...

Page 9: ...rated weight 211kg 465 lbs Floor Flatness Level 2 5cm over 12m 1 over 3 Crate Dimensions and Weight Unit Portability The ProJet 2500 Printing System is equipped with four caster type rollers and four...

Page 10: ...t of the printer to be able to open the material drawer It is recommended that 36 91cm either behind or in front of the printer for service access Behind would allow service to obtain access from the...

Page 11: ...cap vented If the warm cartridge is not vented the wax will contract during cooling and the cartridge s bottom may become at which will prevent re engagement in the MDM More detailed information on th...

Page 12: ...the build process itself can be temperature sensitive within certain limits The operating temperature range should be between 18 28 C 64 82 F optimal temperatures being 18 24 C 64 75 F The facility ai...

Page 13: ...om your 3 D digital data We are dedicated to developing a relationship that extends beyond the terms of the sale Please take the time to contact 3D Systems with questions comments or suggestions about...

Page 14: ...e crating location Operating system and workstation con gurations are compatible and meet the minimum requirements as stated in the Client Workstation Requirements section NETWORK CONNECTION IS INSTAL...

Page 15: ...______________________________________________________________________________ Date _____________________________________________ Please return a copy of the check list by FAXING it to the appropriate...

Page 16: ...ee Number 800 889 2964 Phone Number 803 326 4080 Web www 3dsystems com Email more info 3d systems com For Customer Support Region Telephone Email North America 800 793 3669 3DWW MJM Customer Support 3...

Page 17: ..._____ Address _______________________________________________________________________________________ Italy 39 039 68 904 00 39 039 68 811 56 Marketing IT 3dsystems com Japan 03 5451 1690 03 5451 6630...

Page 18: ...ing the Advance Preparation Checklist Return the completed checklist via the method chosen below Fax to the Account Representative s fax number above Fax to the _______________________________________...

Page 19: ...t damages arising from the use of this document however caused and on any theory of liability This limitation will apply even if 3D Systems or an certi ed partner or representative has been otherwise...

Reviews: