7. Technical Specifications
Projekt Elektronik
MESS - UND REGELUNGSTECHNIK GMBH
Page 96
7.2.6
AS-active-probes – Overview Further Data
class
model
bandwidth
(-3 dB)
active area
temperature
coefficient or.
error
High:
AS-HAP
DC – 35 kHz
0.2 mm²
-0.05 %/K
Normal:
AS-NTP 0,6
DC – 35 kHz
0.2 mm²
-0.03 %/K
AS-NTM
DC – 25 kHz
0.2 mm²
-0.03 %/K
AS-NTM-2
DC – 25 kHz
0.12 mm²
±0,005 %/K
AS-NAP
DC – 35 kHz
0.2 mm²
-0.03 %/K
AS-NTP-Hot-05 DC – 35 kHz
0.5 mm²
±1.0% ±0.2 mT
(6)
AS-NTP-Flex
DC – 0.5 kHz
2 mm²
-0.03 %/K
AS-NTP-Flex
0,6
DC – 35 kHz
0.2 mm²
-0.03 %/K
AS-NCu-Wire
DC – 35 kHz
2 mm²
-0.03 %/K
Low:
AS-LTM
DC – 10 kHz
0.2 mm²
-0.03 %/K
AS-LAP
DC – 10 kHz
0.2 mm²
-0.03 %/K
Ultralow:
AS-UAP Geo-X DC – 0.5 kHz
Ø 5 mm
x 22 mm
±0.1 %/K
AS-UAP Lot
DC – 0.5 kHz
Ø 5 mm
x 22 mm
±0.1 %/K
Table 10
(6) in range of –10 °C to +150 °C