Document Number: MAN0045
Issue: 4.01
Page
13
of
16
RELAY B MODE
Relay B can be configured to perform a
number of different roles. By default the
relay simply mimics the lock relay and
allows loads to be driven or provide voltage
free contacts for other equipment such as
Barriers, Turnstiles etc.
KEYBOARD MODE
By default the keyboards work as simple
access code input. However they can be
used in number of different modes for
access control.
Related User Menus:
01
“Access Code”
Related Engineers Menus:
19 External keyboard * mode
98 Clear Access Code
Code
Behaviour
0
Follow Lock Output
1
Future Use
2
Follow Door Forced
3
Follow Duress
4
Follow Hacker
5
Follow PDO
6
Random Search
7
Follow Fire Input
8
Follow Intruder Input
9
PC Controlled
10
Follow Time Zone
11
Two Stage Lock Release
12
Turnstile Mode
Code
Behaviour
0
Normal Keyboard
1
Card & PIN (A only)
2
Card & PIN (B only)
3
Card & PIN (A & B)
4
Virtual Card (4 Digits)
5
Virtual Card (5 Digits)
6
Virtual Card (6 Digits)
7
Virtual Card (7 Digits)
8
Virtual Card (8 Digits)
9
Card & Code
Status LED will Flash
Enter Engineers Password
* 1 2 3 4 5 6
Select Keyboard Mode menu
* 2 0
Status LED will stop Flashing
Complete & Exit Programming Mode
#
Enter required mode
9
Status LED will Flash
Enter Engineers Password
* 1 2 3 4 5 6
Select Relay B Mode menu
* 0 7
Status LED will stop Flashing
Complete & Exit Programming Mode
#
Enter code for function required
1