5

 

Control with text message  

 

Connect/disconnect 
the unit  

1234 ON

  

Inputs are activated, red diode flashes 

1234 OF

  

Inputs are deactivated, red diode turns off 

Activation of 
output x 

1234 S0

 

Closes output 0. (S0..S1) 

1234 B0 

Breaks output 0. (B0..B1) 

 

1234 P0 

Pulses output 0 for 10 secs. (P0..P1) 

Download  

 

1234 OK 

Downloads information about GSM transmission power 
and battery level 
Example: OK>>OK SQ: xx%  

xx = transmission power in percentage. 25 % is smallest 
acceptable value 

1234 V1 R 

Downloads measurements on analogue input 1. (V1 .. 
V2) 

Connection to the 
Internet 

1234 EH USERNAME 

GPRS traffic starts 

1234 EH 

GPRS traffic stops 

 

Additional control 

The unit can also be controlled by use of the PC program and all functions can be controlled directly on the 
Internet.  

On the print there’s a button with the following three functions: 

1.

 

If button is pressed down while power supply is connected, a “beep” is heard after 7 secs. This resets 
the multiGuard DIN9 to default settings. 

2.

 

If button is pressed down during normal operations a “beep” is heard after 7 secs. If button is 
released immediately hereafter, macro 1 is performed. If no function has been saved on macro 1, 
nothing happens. 

3.

 

If button is pressed down after 7 secs., an additional “beep” will be heard after 14 secs. The 
‘sabotage’ alarm is hereby activated. 

See more in the manual or log on Internet management via www.profort.com

  

Summary of Contents for MultiGuard

Page 1: ...ble 230V 12 24V AC DC If necessary a rechargeable 9V battery 3 Turn on the power A diode is lit After approx 20 sec the diode flashes approx every 2 sec and the unit is ready multiGuard DIN9 interior...

Page 2: ...C program on a computer with Windows Download the program from www profort com Start the program and enter the product key specified on the webpage 3 Enter the number on the COM port that the PC uses...

Page 3: ...A 10 NB 11 NP 25 Delete 1234 N1 Deletes receiver in space no 1 Text on input Add 1234 A0 BREAK TEXT TEXT on input 0 by open break A0 A7 1234 L0 END TEXT TEXT on input 0 by close make L0 L7 Delete 1234...

Page 4: ...of alarm 1234 G0 Output is not activated in case of alarm G null Add macro 0 for return of temperature 1234 M0 TEMP V1 R The unit returns value on analogue 1 e g temperature when a text message with t...

Page 5: ...PRS traffic starts 1234 EH GPRS traffic stops Additional control The unit can also be controlled by use of the PC program and all functions can be controlled directly on the Internet On the print ther...

Page 6: ...nd different voice messages by break and close or command 1234 W2 is selected point 6 7 is performed twice First record message for break 3 secs await tone record message for close 3 secs In case of i...

Page 7: ...AC Max 6 A at 35V DC 10VDC output supply Max 100 mA Inputs digital Max 1V 2 mA GND Min 18V max 30 V 24V DC Inputs analog 0 10V DC 0 4 24mA PT 100 Profort temperature sensor 007995 Serial connections R...

Page 8: ...24 V power supply 9 V rechargeable back up battery acquisition Modbus interface IP 65 box Touch display for set up and programming multiGuard Remote IO 1 relay output 2 senders of infrared codes for h...

Reviews: