6
Model # PRO S-1000HD
“HEAVY DUTY”
•
Fill the reservoir with baby/mineral oil provided. See back of unit
for fill level, the oil level shall be between the minimum level and
the maximum level.
Do not over fill.
•
Attach the air chuck connecter found in the accessory case
•
Attach power cables to the
Smoke Monster
•
Attach Air/Smoke hose to the
Smoke Monster
•
Attach shop air to the
Smoke Monster
.
•
Attach power cables to a fully charged 12V or 24V vehicle
battery.
Do not attach to a battery charger.
•
Power up the HD unit using the
red
power switch on the side.
•
Close the airflow dial on the airflow meter.
•
Select working mode (air mode or smoke mode) on the front,
when selected, the LED next to it will be on.
•
Start the unit operation by pushing the
green
“on” button on the
front, it will start for a 10-minute working cycle.
•
Adjust the test pressure dial on front, the left side gauge will
indicate the pressure reading.
•
You can control the amount of smoke by opening or closing the
airflow dial on front.
•
Unit is now ready to use for diagnostic purposes.
Note:
•
Turn the unit off using the
red
“off” button on the front.
•
Turn the unit on using the
green
“on” button on the front.
•
Air/Smoke mode could be switched during working cycle.
•
Press the
red
“off” button during working cycle will
turn the unit
OFF immediately.
Unit is not applicable for EVAP SYSTEMS !