background image

 

Model Pro S 500T “TURBO”

 

 

Fill the reservoir to full level with baby oil provided. See back of unit 
for fill level. 

Do not over fill

.

 

 

Attach power cables and Air/Smoke Hose to the 

Smoke Monster

 

 

Attach shop air to the 

Smoke Monster

 

 

Attach power cables to a fully charged vehicle battery.  

Do not attach 

to a battery charger

.

 

 

Power up the unit using the 

RED

 power switch on the side.

 

 

Start the unit operation by pushing the 

GREEN

 

“on” button on the 

front.

 

 

Push the 

AIR

 button on front and open the airflow dial.

 

 

Place  your  thumb  over  the  airflow  brass  nozzle  at  the  end  of  the 

hose. The pressure gauge should move close to the black mark. (15” 

of water column pressure).

 

 

Turn the unit 

OFF

 using the 

RED

 

button on the front

 

 

Turn the unit 

ON

 again using the 

GREEN

 

“on” button on the front.

 

 

Press the 

SMOKE

 button on the front. Smoke should begin coming 

out the nozzle in about 20 seconds.

 

 

You  can  control  the  amount  of  smoke  by  opening  or  closing  the 
airflow dial on front.

 

 

Unit is now ready to use for diagnostic purposes.

 

 

Press the 

RED

 button on the front to enable 

Turbo Mode

 and Press 

again anytime to disable it.

 

 
 
 
 

 

 

Summary of Contents for Smoke Monster Pro S 1000HD

Page 1: ...Smoke Leak Locator User Manual For Models Pro S 25 Pro S 75 Pro S 500T Pro S 1000HD Ceramic Heating Technology www proflex plus com ...

Page 2: ...7 Cone Adaptor x 1 EVAP Port Removal Tool x 1 EVAP Port Adaptor Hose x 1 Bottle Oiler x 3 Hook x 1 Packing List for Pro S 500T Main Unit x 1 All in 1 Bladder Blocker x 2 Cap Stopples Varied size x 17 Cone Adaptor x 1 EVAP Valve Removal Tool x 1 EVAP Port Adaptor Hose x 1 Bottle Oiler x 3 Packing List for Pro S 1000HD Main Unit x 1 HD Bladder Blocker x 2 Smoke wand x 1 Stainless ring x 1 Safety cha...

Page 3: ...ycle will begin Open the airflow dial on the airflow meter You can control the amount of smoke by opening or closing the airflow dial on front Within 1 minute smoke will appear Unit is now ready to use for diagnostic purposes Note Pressing the red button again within a working cycle will stop the smoke mode and revert to the air mode immediately There can be some smoke residue in the hose DIAGNOST...

Page 4: ...Push the AIR button on front and open the airflow dial Place your thumb over the airflow brass nozzle at the end of the hose The pressure gauge should move close to the black mark 15 of water column pressure Turn the unit OFF using the RED button on the front Turn the unit ON again using the GREEN on button on the front Press the SMOKE button on the front Smoke should begin coming out the nozzle i...

Page 5: ...you have no leak If the pressure needle does fall you have a leak and need to find it using the smoke TURBO SYSTEM Inject the system with air only to confirm there is a leak run air leak decay test Locate vehicle turbo system Seal the turbo system opening with the All in 1 Bladder Blocker use one Bladder Blocker as a lead and another as a block off Press the RED button on front of the machine to e...

Page 6: ...ow dial on the airflow meter Select working mode air mode or smoke mode on the front when selected the LED next to it will be on Start the unit operation by pushing the green on button on the front it will start for a 10 minute working cycle Adjust the test pressure dial on front the left side gauge will indicate the pressure reading You can control the amount of smoke by opening or closing the ai...

Page 7: ...marks There is a possibility that this unit is inapplicable to some of the vehicle models or systems listed in the diagnosis section due to different countries areas and or years Do not hesitate to contact PROFLEX if you come across such questions We are to help you solve the problem as soon as possible Disclaimer To take full advantage of the unit you should be familiar with the engine All inform...

Page 8: ...ark service mark domain name logo or company name Copyright Information Copyright 2012 by PROFLEX Distribution Inc referred as PROFLEX All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of PROFLEX The information conta...

Page 9: ...stated herein Lifetime Warranty for CERAMIHEAT heater In addition to above PROFLEX offers a Limited Lifetime Warranty for material and workmanship of the CERAMIHEAT heater to the original purchaser of any PROFLEX product that is built with the CERAMIHEAT technology This warranty is valid to the original purchaser who has purchased the product from an authorized dealer and for as long as the origin...

Page 10: ...10 This Page Left Blank Intentionally ...

Page 11: ...11 WARRANTY RECORD Brand Name Model Serial Date of Purchase Dealer of Purchase Company Name Address Contact Name E Mail Phone THANK YOU FOR PURCHASING THIS PROFLEX PRODUCT SMOKE MONSTER ...

Page 12: ...Distribution Inc 63 Lawrence Paquette Drive Champlain New York 12919 For warranty repair or return in CANADA Proflex Distribution Inc 65 Brunswick Montreal Quebec Canada H9B 2N4 A return authorization number RMA must be obtained before returning any merchandise under warranty ...

Reviews: