47
11.9.
Additional parameters
11.9.1.
PBX flags
PBX flags are available in parameter 98 in A-8 program. It is a bit mask. Individual bits are described in the
table below:
Option
Bit number
Weight
lock code blockade (CODE0)
1
+1
lock code blockade (CODE1)
2
+2
lock code blockade (CODE2)
3
+4
lock code blockade (CODE3)
4
+8
RFID0 blockade
5
+16
RFID1 blockade
6
+32
blocking calls to premises
7
+64
Table 13 PBX flags
11.9.2.
RTCC time server (watch)
Setting the time server in the system enables to synchronize the time displayed by all keyboards.
In order to turn on the time server, enter the value 2 in A-8 program in parameter 97. The time
server should be switched on in the control panel that has the most stable environmental
conditions (e.g. in a staircase). This control panel should be connected with other PBXes in the
system.
To set the clock in BM0900 modular base, it is necessary to connect the satellite KDC3915 to it
and set the clock in a satellite. The clock in the modular base will be automatically updated.
In case of purchasing the BM0900, the clock module is optional and usually one installation is
required to install one base with the clock. In this case it is necessary to switch on the RTCC server
in order to synchronize the clock in the whole system (in case there is no keyboard server, after
the reset they will count the time from the beginning of UNIX time
–
from 1970). Switching on the
server in the database without the RTCC module will cause a significant time tuning in the system.