![Prodys ProntoNet User Manual Download Page 86](http://html1.mh-extra.com/html/prodys/prontonet/prontonet_user-manual_1609710086.webp)
Prontonet IP Decoder User Manual v5.4.1.1.doc
86
IP Protocols and compatibility
DNS
HTTP
ICMP
IGMPv2
IPv4 /TCP /UDP :RFC 791, RFC 793, RFC 768, RFC 1112
RIPv2
RTP
o
:RFC 3550, RFC 3551, RFC 2250, RFC 3119,
o
:RFC 3190, RFC 4184, RFC 3555, RFC 3640
SAPv1
:RFC 2974
SDP
:RFC 4566, RFC 3264 (EBU Standard Drafts)
SIPv2
:RFC 3261
SNMPv2
SNTP
Communications Ports
LAN port
10/100 Base-T Ethernet.
Connector type: RJ-45
GPIO Port
7 TTL inputs and outputs.
Inputs: Closure to ground.
Outputs: Open collector. 40 mA Max o 40 VDC max.
RS232 Port
RS232 bi-directional asynchronous
Supports data rates to 38.4 Kbps.
Connector Type: DB9F
VII.3
Power Supply
Main
Universal power Supply
Operating Voltage: 94-250 V
Operating Line frequency: 47-65 Hz.
Out Power : 25W