Procopi Label Bleu VENTURI Installation And Operating Instructions Manual Download Page 7

7/12

2014/02 - Indice de révision : A - Code : 29781

6. 

START UP AND OPERATING RECOMMENDATIONS 

To ensure correction operation of the venturi injector 

dechlorination kit, the opening of the Ø50 ¼ turn 

valve must be adjusted:

1. 

Open the Ø50 ¼ turn valve fully.

2. 

Place the end of the Ø8x12 tube into a small 

recipient  filled  with  water  (such  as  a  glass  of 

water).

3. 

Set the 6-way multi-port valve to back wash.

4. 

Start the filtration pump.

5. 

Close the  Ø50 ¼ turn valve slowly and gradually  

until injection starts. When injection starts, air 

bubbles will be seen moving through the flexible 

Ø8x12 tube. 

6. 

Monitor the flow for a few minutes to make sure 

that injection proceeds properly. Over a 2 minute 

period, between 2 and 10 cl of water will be 

injected (this will depend on the pump used).

7. 

The ¼ turn Ø50 valve setting will not need any 

further adjustment. You may remove the handle 

to prevent it from being accidentally altered.   

Caution: The more closed the ¼ turn valve, the 

lower the back wash flow rate.

 In order to ensure 

an effective back wash, close the valve as little as 

possible (just enough to achieve injection). 

 

7. 

LIMITATIONS OF USE 

 

ƒ

Install the venturi injector head down to  ensure 

smooth injection. 

 

ƒ

Install the container of Neutral at the same height, 

or higher than, the venturi injector. 

 

ƒ

Do not fully close the ¼ turn Ø50 valve during a 

back wash. This could damage the pump.

 

ƒ

Neutral should be protected from light, heat and 

cold.

Safety advice and recommendations 

Recommendations taken from the Neutral material 

safety data sheet:

 

ƒ

Wash hands carefully after use.

 

ƒ

Store out of the reach of children.

 

ƒ

Toxic if ingested.

 

ƒ

In case of ingestion, seek medical advice 

immediately and show the packaging or label to 

the health professional. 

 

ƒ

Store apart from foods, drinks, including animal 

feed.  

 

ƒ

Avoid contact with the eyes.

 

ƒ

Will release a toxic gas on contact with an acid. 

 

ƒ

Do not mix with acids.

 

ƒ

Do not mix with bases.

Troubleshooting
If Neutral is not being injected:

 

ƒ

Check that the venturi injector is correctly 

oriented.

 

ƒ

Make sure that the container of Neutral is not 

lower than the venturi injector.

 

ƒ

Check that the ¼ turn valve is closed just enough 

to allow injection of Neutral.

 

ƒ

Check that the vent in the cap of the container of 

Neutral is not blocked. 

Summary of Contents for Label Bleu VENTURI

Page 1: ...2 2014 02 Indice de r vision A Code 29781 FR Page 1 GB DE Page 5 Seite 9 DECHLORINATEUR VENTURI NOTICE D INSTALLATION ET CONSEILS D UTILISATION lire attentivement et conserver pour utilisation ult rie...

Page 2: ...Neutral pour 166 666l d eau de piscine 4 NOMBRE DE PERSONNES POUR LA POSE ET OUTILLAGE N CESSAIRE Nombre de personne 1 Temps de pose 1 h temps de s chage de la colle Outillage n cessaire Colle pour tu...

Page 3: ...lavage il est donc n cessaire de fermer le moins possible la vanne mais suffisamment pour que l injection se fasse 7 RESTRICTIONS D USAGE Installer l injecteur venturi t te en bas pour assurer une bo...

Page 4: ...4 12 2014 02 Indice de r vision A Code 29781...

Page 5: ...5 12 2014 02 Indice de r vision A Code 29781 GB VENTURI DECHLORINATOR INSTALLATION AND OPERATING INSTRUCTIONS to be read carefully and kept for future reference...

Page 6: ...in the pool to be 2mg l 1litre of Neutral will be required for 166 666 l of pool water 4 TOOLS AND NUMBER OF PEOPLE REQUIRED FOR INSTALLATION Number of people 1 Installation time 1 h glue cure time To...

Page 7: ...back wash close the valve as little as possible just enough to achieve injection 7 LIMITATIONS OF USE Install the venturi injector head down to ensure smooth injection Install the container of Neutra...

Page 8: ...4 turn valve 50 mm PVC pipe 50 mm PN 10 Reducing tee solvent F F 50x50x32 90 elbow F F solvent 32 mm Rigid PVC pipe 16 bar 32 x 27 2 PVC barrel union tapped 1 x solvent 32 mm Venturi injector for dec...

Page 9: ...9 12 2014 02 Indice de r vision A Code 29781 DE VENTURI ENTCHLORUNGSGER T MONTAGE UND BEDIENUNGSANLEITUNG Bitte lesen Sie sich diese Anleitung sorgf ltig durch und bewahren Sie sie auf...

Page 10: ...immbadwasser 1 Liter der Neutralisationsl sung erforderlich 4 WERKZEUGE UND ANZAHL DER ZUR INSTALLATION ERFORDERLICHEN PERSONEN Anzahl der Personen 1 Erforderliche Zeit 1 Std Aush rtezeit f r Kleber E...

Page 11: ...Sie den Venturi Einspritzer mit der Spitze nach unten um ein ungehindertes Einspritzen zu gew hrleisten Bringen Sie den NEUTRAL Beh lter auf gleicher H he oder h her als den Venturi Einspritzer an Sch...

Page 12: ...tapped 1 x solvent 32 mm Venturi injector for dechlorinator Pro REF No DESCRIPTION W 120 mm W 100 mm W 60 mm L 100 mm L 60 mm L 120 mm 7 1 Kugelhahn 1 Verschraubung 50 mm 6 2 Reduzierst ck zum Kleben...

Reviews: