background image

13/16

2011/06 - Indice de révision : C - Code : 0030050

 

Assembling JetVac

 

1.  Connect the feed hose to JetVac with the lock nut.

 

2.  Unfold the filter bag and secure with the velcro ® strip.

 

3.  Mount the balancing float at the rear at a distance of  

 

 

between one and two fingers from the feed hose.

 

4.  Turn the pool filter pump on and let it prime before    

 

 

starting up the JetVac booster pump. 

 
 

5.  Attach the sweep hose, hold it in position with a Rilsan ®  

 

 

clamp.

3

Velcro ® strips

Balancing 
float

Lock nut

Feed hose

 

Check the speed of rotation

 

1.  Before putting JetVac into operation, check the rotations per minute (RPM). For maximum efficiency, the  

 

 

JetVac wheels should turn at between 40 and 45 RPM.  

 

2.  Mark the side of the wheel with a piece of tape. 

 

3.  Switch the booster pump on and submerge JetVac. Count the wheel revolutions for one minute.  

4

 

If the wheel rotates at 

less than 40 revolutions per minute:

 
 

• Check that there is no debris in the quick disconnect strainer.

 

  Carry out a filter back wash and clean out the pre-filter basket and the skimmer(s).

 

• Check the hoses (A), (B) and (C) and the swivel unions (D) and (E) for leaks.

 

• If a valve is mounted on the booster return, open it fully to obtain max water flow rate to JetVac.

 

• If the problem persists despite these measures, increase the booster pump power. 

 

If the wheel rotates at 

more than 45 revolutions per minute:

 
 

• If a valve is mounted on the booster pump return, close it gradually until the wheel RPM is within the correct  

 

  range. 

Sweep hose

Summary of Contents for JetVac

Page 1: ...1 16 2011 06 Indice de r vision C Code 0030050 NETTOYEUR AUTOMATIQUE POUR PISCINE MANUEL D INSTALLATION ET D UTILISATION A lire attentivement et conserver Fran ais page 1 English page 9...

Page 2: ...pi ces qui ne r pondraient pas aux sp cifications du JetVac pourraient emp cher son bon fonctionnement voire l endommager Le JetVac doit tre install par un professionnel Les explications concernant s...

Page 3: ...ide de votre manche t lescopique figure 1 Couper la partie du tuyau d alimentation A correspondant cette profondeur exemple le tuyau d alimentation mesurant 3 m l origine si la profondeur maximum de l...

Page 4: ...ce de r vision C Code 0030050 Raccord mural Longueur superflue Figure 2 B A C L Longueur totale superflue L Conserver la longueur de 300 mm entre le robot et le raccord tournant E Raccord tournant D E...

Page 5: ...du JetVac doivent tourner une vitesse comprise aux environs de 40 45 tours minute 2 Faire un rep re sur le cot de la roue l aide d un morceau de ruban adh sif 3 Mettre la pompe en marche immerger le J...

Page 6: ...t r gl e en usine au droit du plan de base de la buse mais selon la piscine d autres positions peuvent tre mieux adapt es R glage du tuyau de balayage Le tuyau de balayage doit se d placer doucement P...

Page 7: ...nts pour tre s r qu ils tournent librement et remplacer les si n cessaire Le JetVac se d place lentement a V rifier et nettoyer le filtre du connecteur rapide b V rifier que le tuyau d alimentation et...

Page 8: ...8 16 2011 06 Indice de r vision C Code 0030050...

Page 9: ...9 16 2011 06 Indice de r vision C Code 0030050 Automatic pool cleaners Installation and operating instructions To be read carefully and kept for future reference...

Page 10: ...JetVac original parts Other parts may not comply with JetVac specifications and could cause the cleaner to malfunction or could even damage it JetVac should be installed by a professional The installa...

Page 11: ...responds to this depth example the feed hose originally measures 3 m if the max pool depth is 2 40 m cut off 0 60 m 3 Connect the feed hose to the wall fitting with the quick disconnect and pull the f...

Page 12: ...06 Indice de r vision C Code 0030050 Superfluous length Figure 2 B A C Figure 2 L Total super fluous length L Keep the 300 mm length between the rotating union E and the robot E Rotating union D Rota...

Page 13: ...heels should turn at between 40 and 45 RPM 2 Mark the side of the wheel with a piece of tape 3 Switch the booster pump on and submerge JetVac Count the wheel revolutions for one minute 4 If the wheel...

Page 14: ...rection is set in the factory but other positions may be better suited to the pool shape Sweep hose regulation The sweep hose should move gently To increase or decrease the movement of the sweep hose...

Page 15: ...the swivel unions are turning freely replace them if necessary JetVac is moving slowly a Inspect and clean out the strainer on the quick disconnect b Check to make sure that the swivel unions are turn...

Page 16: ...16 16 2011 06 Indice de r vision C Code 0030050...

Reviews: