Congratulations on your purchase of a JetVac automatic cleaner! Thank-you for placing your trust in our product. 
Tried and tested, JetVac will provide you with years of trouble-free service. 
However, like all mechanical devices, it will require regular inspections and maintenance. Before using your JetVac for 
the first time, turn the wheels about twenty times. After winterizing your pool, clean it manually to remove debris (sand, 
stones, leaves, etc.) before putting JetVac to work.
After prolonged use, wear parts will need to be replaced. We strongly recommend that you have your JetVac checked 
over by your local dealer. 
Only use JetVac original parts. Other parts may not comply with JetVac specifications and could cause the cleaner to 
malfunction or could even damage it. 
JetVac should be installed by a professional. The installation instructions provided in this booklet are intended for 
persons qualified to install mechanical equipment and carry out plumbing.

The JetVac cleaner is designed to be driven by a pressurised jet of water generated by a booster pump (not included) 
connected to a dedicated vacuum fitting.  

For JetVac to operate correctly, a booster pump with a power rating between 0.75 and 1.20 kW is recommended. The 
booster pump must be connected to a control panel and installed in accordance with the standard NF C 15-100.

1

2

3

4

5

6

7

8

1.  Filtration bag

2.  Balancing float

3.  Sweep hose

4.  Sweep hose cleaning brush

5.  Cleaner body

6.  Feed hose

7.  Hose float

8.  Quick fit connector with wall fitting

Summary of Contents for JetVac

Page 1: ...1 16 2011 06 Indice de r vision C Code 0030050 NETTOYEUR AUTOMATIQUE POUR PISCINE MANUEL D INSTALLATION ET D UTILISATION A lire attentivement et conserver Fran ais page 1 English page 9...

Page 2: ...pi ces qui ne r pondraient pas aux sp cifications du JetVac pourraient emp cher son bon fonctionnement voire l endommager Le JetVac doit tre install par un professionnel Les explications concernant s...

Page 3: ...ide de votre manche t lescopique figure 1 Couper la partie du tuyau d alimentation A correspondant cette profondeur exemple le tuyau d alimentation mesurant 3 m l origine si la profondeur maximum de l...

Page 4: ...ce de r vision C Code 0030050 Raccord mural Longueur superflue Figure 2 B A C L Longueur totale superflue L Conserver la longueur de 300 mm entre le robot et le raccord tournant E Raccord tournant D E...

Page 5: ...du JetVac doivent tourner une vitesse comprise aux environs de 40 45 tours minute 2 Faire un rep re sur le cot de la roue l aide d un morceau de ruban adh sif 3 Mettre la pompe en marche immerger le J...

Page 6: ...t r gl e en usine au droit du plan de base de la buse mais selon la piscine d autres positions peuvent tre mieux adapt es R glage du tuyau de balayage Le tuyau de balayage doit se d placer doucement P...

Page 7: ...nts pour tre s r qu ils tournent librement et remplacer les si n cessaire Le JetVac se d place lentement a V rifier et nettoyer le filtre du connecteur rapide b V rifier que le tuyau d alimentation et...

Page 8: ...8 16 2011 06 Indice de r vision C Code 0030050...

Page 9: ...9 16 2011 06 Indice de r vision C Code 0030050 Automatic pool cleaners Installation and operating instructions To be read carefully and kept for future reference...

Page 10: ...JetVac original parts Other parts may not comply with JetVac specifications and could cause the cleaner to malfunction or could even damage it JetVac should be installed by a professional The installa...

Page 11: ...responds to this depth example the feed hose originally measures 3 m if the max pool depth is 2 40 m cut off 0 60 m 3 Connect the feed hose to the wall fitting with the quick disconnect and pull the f...

Page 12: ...06 Indice de r vision C Code 0030050 Superfluous length Figure 2 B A C Figure 2 L Total super fluous length L Keep the 300 mm length between the rotating union E and the robot E Rotating union D Rota...

Page 13: ...heels should turn at between 40 and 45 RPM 2 Mark the side of the wheel with a piece of tape 3 Switch the booster pump on and submerge JetVac Count the wheel revolutions for one minute 4 If the wheel...

Page 14: ...rection is set in the factory but other positions may be better suited to the pool shape Sweep hose regulation The sweep hose should move gently To increase or decrease the movement of the sweep hose...

Page 15: ...the swivel unions are turning freely replace them if necessary JetVac is moving slowly a Inspect and clean out the strainer on the quick disconnect b Check to make sure that the swivel unions are turn...

Page 16: ...16 16 2011 06 Indice de r vision C Code 0030050...