 When firebox is installed directly on carpeting, tile or other combustible material, other than wood flooring, the 

firebox must be installed on a metal or wood panel extending the full width and depth of the fireplace. 

 

BUILT-IN FIREPLACE INSTALLATION 

Built-in installation of this firebox involves installing  
firebox into a framed-in enclosure.  This makes  
the front of the fireplace flush with wall. If installing  

 

a built-in mantel above the fireplace, you must  
follow the clearances shown in Figure 2.   
Follow the instructions.  

 

NOTICE:  

Surface temperatures of adjacent walls 

and mantels become hot during operation.  Walls  
and mantels above the firebox may become hot  
to the touch. If installed properly, these temperatures  
meet the requirement of the national product standard.   
Follow all minimum clearances shown in this  
manual.  See Figure 4. 
 

1. 

Frame in rough opening. Use dimensions shown in Figure 3 
for the rough opening.  If installing in a corner, use 
dimensions shown in Figure 8 for the rough opening.  
 
 

2. 

Carefully set firebox in front of rough opening with back of 
fireplace inside wall opening.  
 

3. 

Install gas piping to firebox location. See Installing Gas Line, 
on page 9 and Connecting to Gas Supply in log set owner’s 
manual. 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

Figure 2 – Clearance to Combustibles 

Figure 4 

Figure 3 - Rough Opening for Installing in Wall 

Summary of Contents for PC32VFC

Page 1: ...ecorative type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE PC PC36VFC 701 1101 CAUTION FOR YOUR SAFETY FOR USE ONLY W...

Page 2: ...NG THIS APPLIANCE IMPORTANT Read instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS 32 and 36 Models Model A B C D E F G H I J PC32VFC 2 381 18 515 19 24 060 7 567 21 382 20 718 31 732 29 323 34 25 PC36VFC 2 397 18 870 25 28 770 6 622 26 740 25 949 36 031 33 630...

Page 3: ...low directly into fireplace Avoid any drafts that alter burner flame patterns WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this firebox Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects...

Page 4: ...into the control area of fireplace After servicing always replace screen before operating fireplace 12 Use only provided hood See page 8 QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment The term qualified agency means any individual firm corporation or company...

Page 5: ...be installed in a bedroom unless the maximum BTU rating of the installed vent free log set is less than 10 000 Btu Hr UNPACKING 1 Remove the wrapping film around unit 2 Remove the top packaging and 4 angle beads 3 Remove protective plastic wrap 4 Check for any shipping damage If firebox is damaged promptly inform your dealer where you bought the firebox WATER VAPOR A BY PRODUCT OF UNVENTED ROOM FI...

Page 6: ... aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free fireplaces add moisture to the air Although this is beneficial installing fireplace in rooms without enough ventilation air may cause mildew to ...

Page 7: ... of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances shown in this manual See Figure 4 1 Frame in rough opening Use dimensions shown in Figure 3 for the rough opening If installing in a corner use dimensio...

Page 8: ...lace without hood in place Aim three holes on firebox panel at those on heat insulation board fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebox panel Please see Figure 6A Aim three holes on firebox panel at those on outer firebox top fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebo...

Page 9: ...k local codes for equipment shutoff valve location requirements OPTIONAL BLOWER This model can accept the optional blower and model number is FIB100 If you plan to install or use the optional blower a 120V AC with proper grounding electrical connection must be provided at time of installation NOTE A qualified electrician must connect electrical wiring to duplex outlet for built in installation Fol...

Page 10: ...hen calling Customer Service or your dealer have ready Your name Your address Model and serial number of your fireplace How fireplace was malfunctioning Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 1 877 886 598...

Page 11: ... on 10 of this manual Part Description Part QTY 1 Screen Rod PC32VFC 132 PC32VFC 1 PC36VFC 132 PC36VFC 1 2 Draw Screen PC32VFC 131 PC32VFC 2 PC36VFC 131 PC36VFC 2 3 Louver Assembly PC32VFC 000B PC32VFC 1 PC36VFC 120B PC36VFC 1 4 Magnet FE32A155B 1 5 Blower Fixing Panel PC32VFC 127 1 6 Blower Bracket PC32VFC 126 1 7 Hood FBD32D201 1 PC36VFC 117 1 ...

Page 12: ... ACCESSORY Part Description Part QTY PC32VFC PC36VFC 1 Top Trim FB32D104 1 2 Left Right Trim FB32D121 2 3 Blower Assembly FIB100 1 1 4 Trim Kit TK32 100B 1 BLOWER OPTIONAL ACCESSORY Refer to model FIB100 manual 4 ...

Page 13: ...ginal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenan...

Reviews: