background image

 

11 

PARTS LIST 
 

This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under 
Replacement Parts on 10 of this manual. 

 

Part

.. 

Description 

Part # 

QTY 

1 Screen 

Rod 

PC32VFC-132 (PC32VFC) 

PC36VFC-132 (PC36VFC) 

2 Draw 

Screen 

PC32VFC-131 (PC32VFC) 

PC36VFC-131 (PC36VFC) 

3 Louver 

Assembly 

PC32VFC-000B (PC32VFC) 

PC36VFC-120B (PC36VFC) 

4 Magnet 

FE32A155B 1 

Blower Fixing Panel 

PC32VFC-127 

6 Blower 

Bracket 

PC32VFC-126  1 

7 Hood 

FBD32D201 1 

PC36VFC-117 1 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PC32VFC

Page 1: ...ecorative type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE PC PC36VFC 701 1101 CAUTION FOR YOUR SAFETY FOR USE ONLY W...

Page 2: ...NG THIS APPLIANCE IMPORTANT Read instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS 32 and 36 Models Model A B C D E F G H I J PC32VFC 2 381 18 515 19 24 060 7 567 21 382 20 718 31 732 29 323 34 25 PC36VFC 2 397 18 870 25 28 770 6 622 26 740 25 949 36 031 33 630...

Page 3: ...low directly into fireplace Avoid any drafts that alter burner flame patterns WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this firebox Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects...

Page 4: ...into the control area of fireplace After servicing always replace screen before operating fireplace 12 Use only provided hood See page 8 QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment The term qualified agency means any individual firm corporation or company...

Page 5: ...be installed in a bedroom unless the maximum BTU rating of the installed vent free log set is less than 10 000 Btu Hr UNPACKING 1 Remove the wrapping film around unit 2 Remove the top packaging and 4 angle beads 3 Remove protective plastic wrap 4 Check for any shipping damage If firebox is damaged promptly inform your dealer where you bought the firebox WATER VAPOR A BY PRODUCT OF UNVENTED ROOM FI...

Page 6: ... aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free fireplaces add moisture to the air Although this is beneficial installing fireplace in rooms without enough ventilation air may cause mildew to ...

Page 7: ... of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances shown in this manual See Figure 4 1 Frame in rough opening Use dimensions shown in Figure 3 for the rough opening If installing in a corner use dimensio...

Page 8: ...lace without hood in place Aim three holes on firebox panel at those on heat insulation board fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebox panel Please see Figure 6A Aim three holes on firebox panel at those on outer firebox top fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebo...

Page 9: ...k local codes for equipment shutoff valve location requirements OPTIONAL BLOWER This model can accept the optional blower and model number is FIB100 If you plan to install or use the optional blower a 120V AC with proper grounding electrical connection must be provided at time of installation NOTE A qualified electrician must connect electrical wiring to duplex outlet for built in installation Fol...

Page 10: ...hen calling Customer Service or your dealer have ready Your name Your address Model and serial number of your fireplace How fireplace was malfunctioning Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 1 877 886 598...

Page 11: ... on 10 of this manual Part Description Part QTY 1 Screen Rod PC32VFC 132 PC32VFC 1 PC36VFC 132 PC36VFC 1 2 Draw Screen PC32VFC 131 PC32VFC 2 PC36VFC 131 PC36VFC 2 3 Louver Assembly PC32VFC 000B PC32VFC 1 PC36VFC 120B PC36VFC 1 4 Magnet FE32A155B 1 5 Blower Fixing Panel PC32VFC 127 1 6 Blower Bracket PC32VFC 126 1 7 Hood FBD32D201 1 PC36VFC 117 1 ...

Page 12: ... ACCESSORY Part Description Part QTY PC32VFC PC36VFC 1 Top Trim FB32D104 1 2 Left Right Trim FB32D121 2 3 Blower Assembly FIB100 1 1 4 Trim Kit TK32 100B 1 BLOWER OPTIONAL ACCESSORY Refer to model FIB100 manual 4 ...

Page 13: ...ginal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenan...

Reviews: