Procom PC32VFC User Manual Download Page 4

 

1. 

Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors. 

 
2. 

Do not use this firebox as a wood-burning fireplace. Use only decorative unvented room heaters (log set). 

 
3. 

Keep all air openings in front and bottom of fireplace clear and free of debris. This will ensure enough air for proper 
combustion. 

 
4. 

Do not run fireplace: 

 

Where flammable liquids or vapors are used or stored. 

 

Under dusty conditions. 

 
5. 

Before using furniture polish, wax, carpet cleaner, or similar products, turn fireplace off. If heated, the vapors from 
these products may create a white powder residue within burner box or on adjacent walls or furniture. 

 
6. 

Do not use firebox if it has been under water due to shock hazard that could result with the blower accessory (if 
installed) in place. 

 
7. 

Turn firebox off and let cool before servicing. Only a qualified service person should service and repair firebox. 

 
8. 

Operating firebox above elevations of 4,500 feet could cause pilot outage. 

 
9. 

To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity. 

 
10.  This firebox should not be installed in a bedroom or bathroom. 
 
11.  Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can 

cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. After 
servicing, always replace screen before operating fireplace. 

 
12.  Use only provided hood (See page 8). 
 

QUALIFIED INSTALLING AGENCY 

Only a qualified agency should perform installation and replacement of gas piping, gas utilization equipment or 
accessories, and repair and servicing of equipment. The term “qualified agency” means any individual, firm, 
corporation, or company that either in person or through a representative is engaged in and is responsible for:  

a)  Installing, testing, or replacing gas piping or 

b)  Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar 

with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.  

 
PRODUCT FEATURES  

 

OPERATION 

 
This firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room fireplaces. (Physical 
size limitations apply. Refer to minimum firebox requirements supplied with log fireplace.) It requires no outside 
venting or chimney making installation easy and inexpensive. When used without the blower, the firebox requires no 
electricity making it ideal for emergency backup heat.  

 
 
LOCAL CODES 

 

Install and use fireplace with care. Follow all codes. In the absence of local codes, use the latest edition of 

The 

National Fuel Gas Code

,  ANSI Z223.1, also known as NFPA 54*.  

 
*Available from:  
 
 
 
 
 

  American National Standards Institute, lnc.         National Fire Protection Association, lnc. 
  1430 Broadway                                                    1 Batterymarch Park 

New York, NY 10018                                            Quincy, MA  02269-9101 

Summary of Contents for PC32VFC

Page 1: ...ecorative type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE PC PC36VFC 701 1101 CAUTION FOR YOUR SAFETY FOR USE ONLY W...

Page 2: ...NG THIS APPLIANCE IMPORTANT Read instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS 32 and 36 Models Model A B C D E F G H I J PC32VFC 2 381 18 515 19 24 060 7 567 21 382 20 718 31 732 29 323 34 25 PC36VFC 2 397 18 870 25 28 770 6 622 26 740 25 949 36 031 33 630...

Page 3: ...low directly into fireplace Avoid any drafts that alter burner flame patterns WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this firebox Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects...

Page 4: ...into the control area of fireplace After servicing always replace screen before operating fireplace 12 Use only provided hood See page 8 QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment The term qualified agency means any individual firm corporation or company...

Page 5: ...be installed in a bedroom unless the maximum BTU rating of the installed vent free log set is less than 10 000 Btu Hr UNPACKING 1 Remove the wrapping film around unit 2 Remove the top packaging and 4 angle beads 3 Remove protective plastic wrap 4 Check for any shipping damage If firebox is damaged promptly inform your dealer where you bought the firebox WATER VAPOR A BY PRODUCT OF UNVENTED ROOM FI...

Page 6: ... aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free fireplaces add moisture to the air Although this is beneficial installing fireplace in rooms without enough ventilation air may cause mildew to ...

Page 7: ... of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances shown in this manual See Figure 4 1 Frame in rough opening Use dimensions shown in Figure 3 for the rough opening If installing in a corner use dimensio...

Page 8: ...lace without hood in place Aim three holes on firebox panel at those on heat insulation board fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebox panel Please see Figure 6A Aim three holes on firebox panel at those on outer firebox top fix the firebox with screws pre set on its board by directly inserting screwdriver into holes on top firebo...

Page 9: ...k local codes for equipment shutoff valve location requirements OPTIONAL BLOWER This model can accept the optional blower and model number is FIB100 If you plan to install or use the optional blower a 120V AC with proper grounding electrical connection must be provided at time of installation NOTE A qualified electrician must connect electrical wiring to duplex outlet for built in installation Fol...

Page 10: ...hen calling Customer Service or your dealer have ready Your name Your address Model and serial number of your fireplace How fireplace was malfunctioning Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 1 877 886 598...

Page 11: ... on 10 of this manual Part Description Part QTY 1 Screen Rod PC32VFC 132 PC32VFC 1 PC36VFC 132 PC36VFC 1 2 Draw Screen PC32VFC 131 PC32VFC 2 PC36VFC 131 PC36VFC 2 3 Louver Assembly PC32VFC 000B PC32VFC 1 PC36VFC 120B PC36VFC 1 4 Magnet FE32A155B 1 5 Blower Fixing Panel PC32VFC 127 1 6 Blower Bracket PC32VFC 126 1 7 Hood FBD32D201 1 PC36VFC 117 1 ...

Page 12: ... ACCESSORY Part Description Part QTY PC32VFC PC36VFC 1 Top Trim FB32D104 1 2 Left Right Trim FB32D121 2 3 Blower Assembly FIB100 1 1 4 Trim Kit TK32 100B 1 BLOWER OPTIONAL ACCESSORY Refer to model FIB100 manual 4 ...

Page 13: ...ginal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenan...