Switching on
Check before switching on:
•
Pump with drive safely installed and connected?
•
Connections sealing and connected stress-free?
•
Oil level checked?
•
Quench fluid level OK? Correct pressure set in case of a counter-pressure device?
•
Rotational direction checked?
•
Safety devices (covers and limit switches, safety valve) installed and checked for
function?
1.
Before start up, check pump for contamination and foreign objects.
2.
Fully open pressure and suction-side valves.
3.
Fill pump with medium to enable suction safely.
4.
Switch on drive.
5.
When initially operating the pump, check to see whether it
and the pipe lines are tight.
5.3
Operation
Warning!
Do not operate against closed shut-off devices.
Bursting of the pipe line or downstream system components is possible.
Potential consequences: Severe or fatal injuries.
•
Secure the pump through an approved overpressure protection.
Possible damage to property
•
The pump needs to be cleaned for handling foodstuffs (
→
→
→
→
Commissioning pumps for
handling foodstuffs)
ATTENTION