Chapter 4
EcoTwin_002 EN
Page 4-5
4.8
Driving elements
Warning!
Driving elements are quickly moving during operation.
They can squash hands.
Potential consequences: Severe or fatal injuries.
•
Always cover driving elements with a protective guard.
4.8.1
Coupling elements
ViscoTwin
screw pump with free shaft (cylinder shaft with shaft key) are connected to the drive
through a flexible coupling.
Possible damage to property
•
Do not mount using a hammer
•
Use a pull-on device or heat the coupling half to approx. 90 °C.
(Remove rubber parts before) and mount the coupling in hot condition.
•
The coupling halves must be aligned against each other.
•
When assembling the drive with the pump, it is necessary to adjust
a = Maximum and minimum clearance
b = Angular offset and
c = Axial offset
acc. to the coupling manufacturer's specifications. (Enclosures)
4.9
Mounting and adjusting additional equipment accessories
Mount additional equipment accessories (speed measuring devices, counter-pressure systems)
according to the attached instructions (see Appendix).
ATTENTION
Manual ViscoTwin 104-xx 3A