12
Measuring Process
© 2001 PROCEQ SA
5.2.2
Clear Memory
Objects cannot be deleted individually.
You can only delete the entire memory
contents. This action cannot be undone after it
has been confirmed.
5.2.3
Display Memory
The measurement series number, the impact direction of
the concrete test hammer and the measured rebound
values R after deletion of the outliers, as well as the
average of the rebound values
or of the compressive
strength of the concrete are displayed.
5.2.4
Output on the Printer
For data transmission, use the printer cable
Art. No. 330 00 460. Printing can be performed on all
commercially available printers with a serial port. The
following printing options are available:
- Printer is connected to the display unit during measu-
rement (online):
After completion of a measurement series (the prese-
lected no. of test impacts has been performed), the
data are sent to the printer. Transmission is also pos-
sible at any time by pressing the PRINT key.
- Printing via memory:
In the sub-menu ”Display memory” the desired measu-
rement series can be selected with the
,
keys.
Printing is performed by pressing the PRINT key.
Fig. 5.6
Example of a print protocol
Bedienungsanleitung DIGI-SCHMIDT 2000.qxd 12.12.2002 16:24 Seite E12