Page 1: ...INSTALLATION CONFIGURATION MANUAL PRODMHD11 Single HD Encoder Modulator BLAKE U K LTD 177 187 Rutland Road Sheffield S3 9PT UK TEL 0114 275 9729 FAX 0114 275 6061 https www blake uk com...

Page 2: ...ESCRIPTION 4 FEATURES 4 SPECIFICATIONS 5 INSTALLATION 6 UNPACKING and INSPECTION 6 HARDWARE INSTALLATION and CONNECTIONS 6 MODULATOR SETUP AND CONFIGURATION 7 INITIAL SETUP TO FACTORY DEFAULT 7 MODULA...

Page 3: ...tive The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT power on the unit until all cables and connections to the device have been properly connecte...

Page 4: ...signal into a flexible DVB T Multiplex HDMI inputs with HDMI loop through Video resolution up to 1080p Clean and clear picture of high motion video sports and text crawls rolls etc Programmable via LC...

Page 5: ...p Video Compression H 264 AVC Audio Compression MPEG1 Layer II AAC LCN Yes Carrier OFDM Mode 2K 8K Guard Intervals 1 32 Code Rate FEC 7 8 Constellations QAM64 GENERAL Power Supply 12 VDC 1 5 Amp Consu...

Page 6: ...if there is any indication of defect or damage HARDWARE INSTALLATION and CONNECTIONS 1 Use a HDMI cable to connect the video source e g CATV DVD VCR Camera to the unit s HDMI IN port It is highly rec...

Page 7: ...tup Channel number and LCN For switching between the two parameters press OK button until the arrow flashes Press UP DOWN button to select the desired setup parameter Then press OK again to confirm Ou...

Page 8: ...same time turn ON the unit Release the UP and DOWN buttons when the LCD shows Reset To Default The unit will reset to factory default Caution Once this process is complete the unit will automatically...

Page 9: ...ed LAN setup 1 Power up the Encoder Connect each encoder using a standard CAT5e cable from the Web Management port located on the rear panel of the encoder to a switch Connect a CAT5e cable from the s...

Page 10: ...al V1 1 10 4 Select Local Area Connection Icon Then Right Click Select Properties Internet Protocol Version 4 TCP IPv4 Properties 5 Select Obtain an IP address automatically Obtain DNS server address...

Page 11: ...automatically Select Start Computer Network 7 After selecting Network the encoders will show up on the right side under Media Devices Each device will show up by Device Address ex PROCEPTION 001 002 0...

Page 12: ...8 Welcome page will be displayed as shown figure for example 9 Select the Common Setup tab User will be presented with encoders Authentication Required screen 10 Enter User Name and Password User Name...

Page 13: ...PRODMHD11 Manual V1 1 13 11 Common Setup Remark The Attenuation in the Common Setup is reserved Please adjust the attenuation by adjusting the Gain control from the unit...

Page 14: ...PRODMHD11 Manual V1 1 14 12 RF Setup...

Page 15: ...PRODMHD11 Manual V1 1 15 13 Encoder Setup...

Page 16: ...PRODMHD11 Manual V1 1 16 14 Network Setup...

Page 17: ...PRODMHD11 Manual V1 1 17 15 Administration...

Page 18: ...WS 8 SETTINGS Windows 8 Settings If using Windows 8 PC move the mouse to the bottom or top right corner of the screen and select Settings Select Control Panel In the Control Panel window select Catego...

Page 19: ...PRODMHD11 Manual V1 1 19 Select Network and Sharing Centre Select Change Adapter Settings Right click on your connected network and select Properties...

Page 20: ...Properties Select Use the following IP address and Use the following DNS server addresses to change your computer s IP address and or DNS server addresses To get IP settings automatically using DHCP...

Page 21: ...PRODMHD11 Manual V1 1 21 PRODMHD11 HD Encoder Modulator Notes PRODUCT NOTES ITEM VALUE DEVICE NAME PURCHASE DATE INSTALLATION DATE SERIAL NUMBER FIRMWARE VERSION...