Probewell Lab Inc.
Page
•
28
Example 1: Quick Test - Solid-state 9S meter
Meter:
Solid-State, Form 9S
Voltage:
120-480V
Kh:
1.8
TA:
2.5
CL:
20
Accessory:
Optical Pickup
A Quick Test
consists in applying loads on the meter for at least 20 seconds (the time
can be modified) for each loads HL, PF and LL. Please note that the three potential
coils of the meter are automatically switched in parallel by the socket.
1.
Connect the optical Pickup
To connect the cables:
•
Plug the RJ12 connector of the straight cable of the Optical Pickup into the
I/O port of the socket.
•
Look for the LED output pulse of the meter and position the suction cup of
the Optical Pickup over it.
Note:
An optional adapter may be required on some meters and can be purchased
as an option.
2.
Performing a Quick Test
Once the installation is completed and the connection to the socket and meter setup
is done (see previous section), we can proceed with the test.
Select
Quick Test
.
Start the sequence; the load current will increase to HL; the meter will start to send
pulses and the internal electronic standard will begin to register the energy that
passes through the meter. The test can be stop at any time.
In addition to the test parameters appearing on the display, the operator can see the
voltage and current applied to the meter, the chronometer and the cumulated
energy registered by the electronic standard.
While testing, you can check the partial results of the test scrolling up and down the
screen. You will get the results as they are done.
3.
Obtaining and saving Test Results
After the three test points, the watthour measurement period ends automatically.
Then, the load is removed, and three test results are displayed: one for HL, one for
Summary of Contents for MT-1/WT3
Page 1: ...MT 1 WT3 USER GUIDE HIGH ACCURACY THREE PHASE WIRELESS WATTHOUR METER TESTER...
Page 9: ...Probewell Lab Inc Page 8...
Page 12: ...MT 1 WT3 User Guide Page 11 Side View of the Socket Fig 2 2 Side View of the Socket...
Page 21: ...Probewell Lab Inc Page 20...
Page 43: ...Probewell Lab Inc Page 42...
Page 47: ...Probewell Lab Inc Page 46...
Page 49: ...Probewell Lab Inc Page 48 Form 1S...
Page 50: ...MT 1 WT3 User Guide Page 49 Form 2S...
Page 71: ...Probewell Lab Inc Page 70 Form 12S 25S 3N N Network...
Page 72: ...MT 1 WT3 User Guide Page 71 Form 12S 25S 3 25S Delta...
Page 73: ...Probewell Lab Inc Page 72 Form 14S 4Y s...
Page 74: ...MT 1 WT3 User Guide Page 73 Form 15S 4...
Page 75: ...Probewell Lab Inc Page 74 Form 16S 4Y...
Page 77: ...Probewell Lab Inc Page 76...
Page 83: ...Probewell Lab Inc Page 82...
Page 85: ...Probewell Lab Inc Page 84 Notes...
Page 86: ...www probewell com Probewell Lab Inc Printed in Canada Edition 2 2...