Probewell Lab Inc.
Page
•
12
Identification
Description
Rear Tabs
The rear tabs connect the socket to the front jaws of the
meter base. The socket gets its power directly from the
meter base (100-600VAC) circuit. The service current
shorting bars (bypasses) are rated for high capacity
amperage.
Removable Tabs
These tabs can be positioned at 3, 5, 6, or 9 o'clock
position as required by the meter base where the test is
conducted. See Appendix C.
Form Selector
In position 1S, 2S, and 15S, the unit is powered from the
two upper tabs. In position 3S, 12S, 14S and 16S, the unit
is powered from the Phase C and the neutral tab. In
position 4S, 6S, 8S and 9S the unit is powered from the 3
and 9 o'clock tabs.
Circuit Breakers
Protection for the MT-1/WT3 and the meter. Two circuit
1A breakers which can be reset by pressing a spring-
loaded button.
Power Switch
Socket's main power on/off switch.
Front Jaws
The front jaws are controlled by internal relays allowing
to test meters. The front jaws become live only when a
meter is inserted. The voltage on the front jaws is current
limited for additional protection.
Pistons
These are actuated by the small lugs on the back of the
meter when inserted for testing.
I/O Connector
Isolated full-duplex communication port. It also provides
an isolated and current limited low voltage supply for the
accessories (optical pickup and metercam) and the
optional handheld remote control.
QR Code Sticker
The QR code sticker contains the access point
information to be scanned for a mobile device as well as
the MAC address.
LED
Socket Status Indicator.
Magnetic Switch
Switch for any manual entry using a magnet.
Air Vent
(1)
Warm air exit. A 5 CFM miniature fan forces air
circulation inside the socket.
Air Inlet
(1)
Cool air input. Filtered through polyurethane foam filter.
(1)
Do not block air circulation. Keep away from direct heat or flame.
Summary of Contents for MT-1/WT3
Page 1: ...MT 1 WT3 USER GUIDE HIGH ACCURACY THREE PHASE WIRELESS WATTHOUR METER TESTER...
Page 9: ...Probewell Lab Inc Page 8...
Page 12: ...MT 1 WT3 User Guide Page 11 Side View of the Socket Fig 2 2 Side View of the Socket...
Page 21: ...Probewell Lab Inc Page 20...
Page 43: ...Probewell Lab Inc Page 42...
Page 47: ...Probewell Lab Inc Page 46...
Page 49: ...Probewell Lab Inc Page 48 Form 1S...
Page 50: ...MT 1 WT3 User Guide Page 49 Form 2S...
Page 71: ...Probewell Lab Inc Page 70 Form 12S 25S 3N N Network...
Page 72: ...MT 1 WT3 User Guide Page 71 Form 12S 25S 3 25S Delta...
Page 73: ...Probewell Lab Inc Page 72 Form 14S 4Y s...
Page 74: ...MT 1 WT3 User Guide Page 73 Form 15S 4...
Page 75: ...Probewell Lab Inc Page 74 Form 16S 4Y...
Page 77: ...Probewell Lab Inc Page 76...
Page 83: ...Probewell Lab Inc Page 82...
Page 85: ...Probewell Lab Inc Page 84 Notes...
Page 86: ...www probewell com Probewell Lab Inc Printed in Canada Edition 2 2...