IMPORTANT SAFEGUARDS 

When  using  electrical  products,  especially  when  children  are  present,  basic  safety  present,  basic  safety 
precautions should always be followed, including the following: 

         

 
 
Danger 

To reduce the risk of electrocution: 

 

 

Always unplug this product immediately after use. 

 

Do not use while bathing. 

 

Do not place or store product where it can fall or be pulled into a tub or sink. 

 

Do not place in or drop into water or other liquids. 

 

Do not reach for a product that has fallen into water. Unplug immediately. 

 
Warning 

To reduce the risk of electrocution or injury to persons: 
 

 

A product should never be left unattended when plugged in. 

 

Close supervision is necessary when this product is used by, on, or near children or invalids. 

 

Use this product only for its intended use as described in this manual. 

 

Do not use attachments not recommended by the manufacturer.

 

 

Never operate this product if it has a damaged cord or plug, if it is not working properly, if it   
has  been  dropped  or  damaged,  or  dropped  into  water.  Return  the  product  to  a  service  center  for 
examination and repair. 

 

Keep the cord away from heated surfaces. 

 

Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where 
the air openings may be blocked. Keep the air openings free of lint, hair, and the like. 

 

Never drop or insert any object into any opening or hose. 

 

Do not use outdoors or operate where aerosol (spray) products are being used. 

 

Connect this product to a properly grounded outlet only.   

 

Do  not  disassemble,  repair  or  rebuild  the  product  without  permission,  otherwise  may  has  risk  of  fire 
and danger in life.   

 

Grounding 

Before  any  connection  is  made,  make  certain  that  this  product  shall  be  connected  to  a  protective  earth 
conductor via the three-wire power cord; the three-blade plug shall be inserted only into a socket outlet that 
provides a protective earth contact.   

 

 

STATEMENTS 

 

Note 

Indicates some tips or some information users should be aware of. 
 

Caution 

Indicate  correct  operating  or  maintenance  procedure  in  order  to  prevent  damage  to  or  destruction  of  the 
equipment or other property. 
 

Summary of Contents for Protekt Aire 4000DX

Page 1: ...Operation Manual FOR Protekt Aire 4000DX 5000DX 270 Washington Street Mount Vernon New York 10553 Phone 1 855 BE PROACTIVE 855 237 7622 Fax 845 205 6005 www proactivemedical com...

Page 2: ...GE CONTENTS 4 PRODUCT FUNCTION 5 Pump 5 Mattress 5 SYSTEM INSTALLATION 6 OPERATION 7 9 General 7 CPR function 9 Pressure set up 9 Low pressure warning 9 CLEANING 10 ENVIRONMENT REQUIREMENTS 11 HANDLIN...

Page 3: ...erly if it has been dropped or damaged or dropped into water Return the product to a service center for examination and repair Keep the cord away from heated surfaces Never block the air openings of t...

Page 4: ...e recommended to use Protekt Aire 4000DX 5000DX system The Protekt Aire 4000DX 5000DX system has been tested and certified for the following standards CE UL Intended Use The Protekt Aire 4000DX 5000DX...

Page 5: ...lowing items should be missing or damaged please contact your local dealer or service center for replacement immediately Pump Unit Mattress Cover Sheet Optional The cover sheet makes cleaning an easy...

Page 6: ...weight Alarm Mute 3 The audible alarm turns on when the mattress pressure is low Press the button to mute alarm Static mode 4 Press to set the air mattress in static therapy mode The function will re...

Page 7: ...hment of the Mattress Replacement does not interfere with the movement or operation of the bed Pump Unit Activation a Position Control Unit by hanging hooks over foot board of the bed or place unit on...

Page 8: ...120 mmHg This may result in cell damage DO NOT change any component by yourself If there is need for replacement or repair always contact your local dealer For patients When the pressure has been adj...

Page 9: ...specific requirements NOTE Press the static mode button from the touch panel to provide a firm surface that makes it easier for the patient to transfer or reposition The static mode can support the pa...

Page 10: ...uggestion from a health care professional Low pressure warning When abnormal pressure occurs the Low Pressure indicator will come on For some types of pumps the alarm will be activated to alert of a l...

Page 11: ...d be wet thoroughly with 1 9 Hypochiorite solution 1 part bleach to 9 parts water and allow drying for at least 10 minutes Then blot with a clean damp cloth Unzip the top cover from the mattress Brush...

Page 12: ...in the pump unit and check the airflow from the hose connection port The airflow should alternate between ports every half cycle time Check the air hoses to see if there are any kinks or breaks For re...

Page 13: ...on PU Pressure range 20 mmHg 50 mmHg Air cells Nylon PVC Cycle time 10 min Base Nylon PVC Case Material Flame Retardant ABS Protekt Aire 4000DX 20 air cells Protekt Aire 5000DX 17 air cells Static Mod...