PRO SIGNAL PSG04175 Manual Download Page 8

- 8 - 

Distance  between  transmitters  and
receiver too 

great.

Reduce distance between transmitters and receiver to receive
signal

.

High  shielding  materials  between  the
units  (thick  walls,  steel,

 

concrete,

isolating aluminum foil and etc)

.

Find a different location for sensors and/or receiver. See
also item 

‘transmission range’ below

.

Interference  from  other  sources
(e.g. wireless

 

headset, speaker

 

etc.

operating on the same frequency)

.

Find a different location for the sensors and/or base station.
Neighbo

u

rs using electrical devices operation on the same

signal frequency can also cause interference with reception

.

No  reception  after  adding  extension
cables

.

Find a new location for the sensors and/or base station.

Poor contrast LCD or no reception

from sensors.

Low batteries in sensors or receiver.

Change batteries

.

Temperature, humidity, or air pressure
is incorrect.

Check/replace batteries. If multiple remote sensors are in use,
check  location  with  corresponding 

“boxed  numbers”. Or move

away from sources of heat/cold. Adjust relative air pressure to a
value from a reliable source (TV radio, etc.).

7. Specifications

Outdoor data 

Transmission distance in open field
Frequency
Temperature range
Resolution
Measuring range rel. humidity
Humidity accuracy

:

:
:
:
:
:

:

:

:

:

:

:

:

:

:

:

100meter max.
433MHz

-40

 to +60

 (

displays

 OFL if outside range)

0.1

20%

95%

+/-5% 

within 

0-45

48 sec
IPX3

48 sec
0

 to +60

 

0.1

 

10%

99% 

1%
919hPa 

–1080hPa

0.1hPa/1.5hPa
120 sec

Measuring interval thermo-hygro sensor
Water proof level

Indoor data 

Pressure / temperature
Indoor temperature range
Resolution
Measuring range rel. humidity
Resolution
Measuring range air pressure
Resolution/Accuracy
Alarm duration

Power consumption 

Base station

 

Remote sensor
Battery life

3XAA 1.5V LR6 Alkaline batteries
2xAA 1.5V LR03 Alkaline batteries
Minimum 12 months for base station

Minimum 24months for remote sensor 

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & 

ELECTRONIC EQUIPMENT

These symbols indicate that separate collection of Waste Electrical and Electronic Equipment 

(WEEE) or waste batteries is required. Do not dispose of these items with general household waste. 

Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned 

to any waste battery recycling point which are provided by most battery retailers. Contact your local 

authority for details of the battery and WEEE recycling schemes available in your area.

Made in China. PR2 9PP

Man Rev 1.0

7. Problems and interference with operation

Problem & cause

Remedy

:

:

:

Summary of Contents for PSG04175

Page 1: ...d should be kept in a safe place for future reference It contains important notes on setup and operation 2 2 2 2 4 5 5 5 5 5 6 7 8 8 3 3 3 4 7 y Do not expose the main unit to rain or moisture y Use o...

Page 2: ...ll pick up the signal from the transmitter To measure outdoor temperature place the transmitter outdoors It will transmit the temperature from its location Every time the remote sensor is powered up f...

Page 3: ...educe the range If a north facing wall is not possible choose a shaded area under an eve 1 Use a screw or nail to affix the remote sensor to the wall 2 Hang the remote sensor up using string or a zip...

Page 4: ...ure display 22 General outdoor alarm icon 23 Weather tendency indicator 24 Barometer air pressure 25 Pressure display unit inHg or hPa 26 Pressure alarm on indicator 4 2 Weather forecasting Sunny Part...

Page 5: ...uires a higher setting compared to an area where the air pressure is stagnant For example if 4hPa is selected then there must be a fall or rise in air pressure of at least 4hPa before the weather stat...

Page 6: ...particular alarm will sound and flash for 120 second Press any key to mute the alarm When weather alarm condition was activated again within 10 minutes alarm will not sound but will continue to flash...

Page 7: ...aximum value will be reset to current reading 1 Indoor humidity maximum 2 Indoor temperature maximum 3 Outdoor humidity maximum 4 Outdoor temperature maximum 5 Outdoor dewpoint maximum 6 Pressure maxi...

Page 8: ...ield Frequency Temperature range Resolution Measuring range rel humidity Humidity accuracy 100meter max 433MHz 40 to 60 displays OFL if outside range 0 1 20 95 5 within 0 45 48 sec IPX3 48 sec 0 to 60...