3.2 Mounting 

1)

Base station

With one foldable leg at the back of the unit, the base station can be placed onto any flat surface or wall

mounted at the desired location by the hanging holes also at the back of the unit. It is important to check

that the radio signal can be received before permanently mounting any of the units

2)

Remote sensor

To achieve a true temperature reading, avoid mounting remote sensor in direct sunlight. We recommend

that you mount the remote sensor on an outside 

n

orth-facing wall; obstacles such as walls, concrete, and

large metal objects  will reduce the range.  If a north facing wall is not possible, choose  a shaded area,

under an eve.

1.

Use a screw or nail to affix the remote sensor to the wall.

2.

Hang the remote sensor up 

using

 string or 

zip tie.

Note: 

Make sure the sensor is mounted vertically and not lying down on a flat surface. This will insure 

optimum reception. Wireless signals are impacted by distance, interference (other weather stations, 

wireless phones, wireless routers, TVs and computer monitors), and transmission barriers, such as walls. 

In general, wireless signals will not penetrate solid metal and earth (down a hill, for example). 

4. LCD overview

4.1 LCD overview

 

The following illustration shows the full segments of the LCD for description purposes only and will not 

appear like this during normal operation. 

Summary of Contents for PSG04175

Page 1: ...d should be kept in a safe place for future reference It contains important notes on setup and operation 2 2 2 2 4 5 5 5 5 5 6 7 8 8 3 3 3 4 7 y Do not expose the main unit to rain or moisture y Use o...

Page 2: ...ll pick up the signal from the transmitter To measure outdoor temperature place the transmitter outdoors It will transmit the temperature from its location Every time the remote sensor is powered up f...

Page 3: ...educe the range If a north facing wall is not possible choose a shaded area under an eve 1 Use a screw or nail to affix the remote sensor to the wall 2 Hang the remote sensor up using string or a zip...

Page 4: ...ure display 22 General outdoor alarm icon 23 Weather tendency indicator 24 Barometer air pressure 25 Pressure display unit inHg or hPa 26 Pressure alarm on indicator 4 2 Weather forecasting Sunny Part...

Page 5: ...uires a higher setting compared to an area where the air pressure is stagnant For example if 4hPa is selected then there must be a fall or rise in air pressure of at least 4hPa before the weather stat...

Page 6: ...particular alarm will sound and flash for 120 second Press any key to mute the alarm When weather alarm condition was activated again within 10 minutes alarm will not sound but will continue to flash...

Page 7: ...aximum value will be reset to current reading 1 Indoor humidity maximum 2 Indoor temperature maximum 3 Outdoor humidity maximum 4 Outdoor temperature maximum 5 Outdoor dewpoint maximum 6 Pressure maxi...

Page 8: ...ield Frequency Temperature range Resolution Measuring range rel humidity Humidity accuracy 100meter max 433MHz 40 to 60 displays OFL if outside range 0 1 20 95 5 within 0 45 48 sec IPX3 48 sec 0 to 60...

Reviews: